Samson 1060 Parts And Technical Service Manual Download Page 6

 

 
 

 

 

 

 

 

Symptoms Possible 

Reasons 

Solutions 

Y-Strainer clogged with debris. 

De-pressurize the system and clean the 
screen. 

Fluid Solenoid clogged CLOSED with 
debris. 

De-pressurize the system and clean the 
screen. 

Ready Light and Fluid Solenoid wired in 
Series Circuit. 

Rewire in Parallel Circuit. 

Impulse meter inlet screen clogged. 

De-pressurize the system and clean the 
screen. 

Control Handle inlet screen clogged 

De-pressurize the system and clean the 
screen. 
Check air supply to pump.  
Bleed air from product piping. 
Check function and wiring of Air 
Solenoid, if used. 

Pump not operating properly. 

Diagnose pump using the proper 
troubleshooting manual. 

DFC Ready Light ON. 
Ready Light at Station ON. 
No Product flow at Dispense Point. 

No product in bulk tank or drum.

Fill bulk tank or replace drum. 

Pre-Set 

amount 

too 

high. 

Re-Authorize a dispense using the 
Operation section of this manual. 

Wiring from DFC to Impulse Meter. 

Trace and Repair. 

Wire connections at Impulse Meter 

Check for tightness, continuity and that 

the correct terminals on the Impulse 
meter are used. 

Impulse Meter incorrectly plumbed. 

IN the bottom, OUT the side. 

Impulse Meter micro-switch out of 
adjustment.  

Readjust and test. 

Impulse Meter micro-switch defective. 

Test and replace. 

Impulse Meter rotary cam set screw 
loose – cam not turning. 

Tighten the setscrew. 

Impulse Meter defective. 

Replace. 

Fluid Solenoid incorrectly plumbed. 

IN the side, OUT the bottom. 

Fluid Solenoid clogged OPEN with 
debris. 

De-pressurize the system and clean the 
valve parts and screen. 

DFC Ready Light ON. 
Ready Light at Station ON. 
Product flow at Dispense Point will not 
stop. 

Fluid Solenoid defective.

Replace.

Operator Error. 

Check Pre-Set function - test delivery 

and re-train operator. 

System Accuracy limitations. 

See  the Special Diagnostic Procedures 
on accuracy below. 

Wiring to Impulse Meter. 

Check for tightness and continuity. 

Impulse Meter micro-switch out of 
adjustment. 

Readjust and test. 

Impulse Meter micro-switch defective. 

Replace. 

Impulse Meter rotary cam set screw 
loose – cam turning intermittently. 

Tighten the setscrew. 

Impulse Meter defective. 

Not likely – see the special diagnostic 
procedures below. If defective replace. 

All Stations always deliver too much 

product before shutting off. 

DFC Console defective. 

Not likely – see the special diagnostic 
procedures below. If defective replace.

Operator Error. 

Check Pre-Set function - test delivery 
and re-train operator. 

System Accuracy limitations. 

See  the Special Diagnostic Procedures 
on accuracy below. 

Impulse Meter rotary cam set screw 
loose – cam turning intermittently. 

Tighten the setscrew. 

One or Some of the Stations always 
delivers too much product. 

Fluid Solenoid action impaired by 
debris.

De-pressurize the system and clean the 
valve parts and screen. 

Operator Error. 

Check Pre-Set function - test delivery 
and re-train operator. 

Wiring to Impulse Meter. 

Check for tightness and continuity. 

Impulse Meter micro-switch out of 
adjustment – double clicking. 

Readjust and test. 

Air leaks in Pump suction. 

Reseal Pump suction tube. 

All Stations always do not deliver 
enough product before shutting off. 

Foot valve on Pump missing, not sealed 
or defective.

Replace, Reseal, or Repair. 

1060 

Troubleshooting Continued

 

 

 Samson Corporation-Swannanoa, NC 28778-

  800.311.1047 www.samsoncorporation.com

  

 

Summary of Contents for 1060

Page 1: ...FC est con u pour l usage comme une commande positive centrale d une vari t de fluides tels que l huile de moteur l huile de vitesse et ATF Incluses un compteur pr r gl et un totalisateur non r glable...

Page 2: ...ituada sobre el contador que totaliza iluminar la secci n superior del p exhibici n reajustar a 0 0 y la estaci n seleccionada es lista dispensar el producto El metro preestablecido cuenta PARA ARRIBA...

Page 3: ...cated at each dispense point St nd choose the cable For cable runs under 400 feet use 18 gauge stranded nd choose the cable For cable runs under 400 feet use 18 gauge stranded o o n n CAUTION Do not u...

Page 4: ...om the Ready Light and connect them using a wire nut to the appropriately colored station wire using the chart above and the previously prepared map of t shop Connect the two wires indicated in the ch...

Page 5: ...um Fluid Pressure Oil Presi n de fluido m xima Aceite 180 bar 3000 PSI Maximum Fluid Pressure H20 Presi n de fluido m xima H20 15 bar 250 PSI Minimum Flow Flujo M nimo 1 l min GPM Maximum Flow Flujo M...

Page 6: ...Ready Light at Station ON Product flow at Dispense Point will not stop Fluid Solenoid defective Replace Operator Error Check Pre Set function test delivery and re train operator System Accuracy limit...

Page 7: ...the bottom OUT the side Impulse Meter micro switch out of adjustment Readjust and test Impulse Meter micro switch defective Test and replace Impulse Meter rotary cam set screw loose cam not turning Ti...

Page 8: ...is mounted on a plastic adjusting base if the pulses are uneven adjust it appropriately in or out until the Impulse Meter pulses perfectly Reconnect the wires at the Impulse Meter and then disconnect...

Reviews: