11
| DOC9063L
Ocean Master 1000
A failure to comply with the requirements for storing the pump may result in internal
damage to the device
2.5 Pump storage and draining procedure
The pump’s service liquid is drained on delivery, and the pump can be immediately stored in accordance
with the technical specifications.
After operation, the pump can be stored for 30 days without further action.
If the pump remains out of operation for a longer period of time after use, its service liquid must be
drained, and the liquid supply to the pump must be shut off.
When emptying the pump, it is important that all chambers inside the pump are emptied.
The pump can be fitted with valves in the draining connections. See below.
After use with sea water it is recommended to drain and flush the pump with fresh water.
If the temperature is below freezing point of the service liquid, it could damage the pump
Under these conditions, the pump must be drained completely
All plugs and protective covers must be fitted during storage