4.4 Drive
The pump can be connected through direct or belt drive.
The unit (pump & motor) must be installed on a stable foundation, which
must be level and stable, so that the unit is not twisted or exposed to a
profile distortion.
Misalignemt tolerances must be complied. See illustration to the right
for misalignment types.
4.4.1 Direct drive
4.4.2 Belt drive
DOC1611500_1
DOC1611500_1
DOC1611501_1
DOC1611501_1
For belt drive, it must be ensured that the permissible radial force is not exceeded. See specifications.
DOC11754
Offset misalignment
Angular misalignment
Angular misalignment :
0,08 mm / 100 mm
Offset misalignment :
0,1 mm
Angular misalignment :
0,87 mm / 100 mm
Offset misalignment :
0,1 mm