SamplexPower RC-15A Owner'S Manual Download Page 4

SECTION 4 | 

INSTALLATION

Please refer to fig. 1. The Remote Control can be flush mounted on a wall or a 
panel by making a suitable cut out to accommodate the projection in the back. 
Connect one end of the cable set to the RJ-12 / RJ-25 Modular Jack (5) at the 
back of the Remote and the other end to the RJ-12 / RJ-25 Jack on the inverter. 
Ensure that the connection is firm and the tab on the plug securely locks in the 
jack. 

SECTION 5 | 

OPERATION

Please refer to fig 1. Please also refer to the owner’s Manual of the inverter for  
associated details. 

NOTE: 
for the Remote Control to operate, the oN/off Switch on the inverter 
is required to be in oN condition to activate the control circuitry for 
the Remote Control. 

Switch oN the inverter first with the help of the Power oN/off Switch on the 
inverter. The output of the inverter can now be switched off/oN by pressing 
the oN/off Push button (1).

See under heading “LED Display” above for information on the operating con-
ditions displayed. Read the owner’s Manual of the inverter for troubleshooting 
abnormal conditions indicated by the LeDs.

No Load Current Draw

As stated above, the oN/off Switch on the inverter is required to be in oN 
condition for the Remote to operate. When the ON/OFF switch on the Remote 
Control is turned oN, all the circuitry inside the inverter becomes fully alive and 
the AC output is made available. In this condition, even when no load is being 
supplied (or, if a load is connected but has been switched off), the inverter 
draws a small amount of current from the batteries to keep the circuitry alive 
and is ready to deliver the required power on demand. This is called the “idle 
current” or the “no load current draw”. When the inverter is turned OFF using 
this Remote Control, some control circuitry is still alive in the inverter and will 
require very small current draw. Hence, when the load is not required to be 
operated, turn off the oN/off Switch on the inverter to prevent unnecessary 
current drain from the battery.

Summary of Contents for RC-15A

Page 1: ...Remote Control for Inverter RC 15A Please read this manual before operating your RC 15A Remote Control Owner s Manual ...

Page 2: ... set with RJ 12 RJ 25 Modular Plugs 6P6C The conductors of the cable set have crossed over rolled over connec tions on the two RJ 12 RJ 25 plugs SECTION 3 LAYOUT OF CONTROLS INDICATIONS DIMENSIONAL DRAWING Fig 1 shows the layout of controls and indications and dimensional drawing LEGEND 1 ON OFF Push Button 2 RED LED Overload 3 RED LED Over Temp 4 GREEN LED Power 5 6P6C Modular Jack for connecting...

Page 3: ...he RJ 12 RJ 25 Modular Jack 5 at the back of the unit is given at Fig 2 below Fig 2 Remote Control RC 15A Pinout of Modular Jack RJ 12 RJ 25 The standard numbering system of the pins of a Modular Jack when looking into the Jack is from left to right As the conductors of the cable are cross connected rolled over the pinouts at the Modular Jack in the inverter will be a mirror image of the pinout of...

Page 4: ...nder heading LED Display above for information on the operating con ditions displayed Read the Owner s Manual of the inverter for troubleshooting abnormal conditions indicated by the LEDs No Load Current Draw As stated above the ON OFF Switch on the inverter is required to be in ON condition for the Remote to operate When the ON OFF switch on the Remote Control is turned ON all the circuitry insid...

Page 5: ...th crossed over rolled over connections Length 5M 16 5 ft Operating Temperature Range 0 C to 40 C 32 F to 104 F Dimensions L x W x D 90 x 64 4 x 27 9 mm 3 54 x 2 54 x 1 1 in Weight without cable Weight with cable 62 gm 174 gm 0 03 lb 0 08 lb NOTE Specifications are subject to change without notice SAMLEX AMERICA BATTERY CAR BATTERIES ...

Reviews: