SamplexPower RC-15A Owner'S Manual Download Page 3

 

LED Display

The following LeD displays are available:
•  Green LED (4) marked POWER. This LED will be lighted when the inverter is 

in ON condition. When the inverter is in OFF condition, this LED will not be 
lighted. This LeD shows that DC input is available to the inverter and that 
the input section of the inverter is operating normally 

•  Red LED (2) marked OVER LOAD. When lighted, it indicates that the AC 

output of the inverter has been shut down due to over load

•  Red LED (3) marked OVER TEMP. When lighted, it indicates that the AC 

output of the inverter has been shut down due to over temperature

ON/OFF Control
oN/off Push button (1) is used to switch oN and switch off the inverter.

Pinout Of Rj-12 / Rj-25 Modular jack
The pinout of the RJ-12 / RJ-25 Modular Jack (5) at the back of the unit is given 
at fig. 2 below:

 

Fig. 2  Remote Control RC-15A - Pinout of Modular Jack RJ-12 / RJ-25 

The standard numbering system of the pins of a Modular Jack, when looking 
into the Jack, is from left to right. As the conductors of the cable are cross-
connected (rolled-over), the pinouts at the Modular Jack in the inverter will 
be a mirror image of the pinout of the Modular Jack in the Remote Control as 
shown below:

Pinout of Modular jack on 

the Remote Control

1

  

Signal

Pinout of Modular  

jack on the inverter

1

LED - “OVER LOAD”

6

2

Toggle

5

3

Ground / Common

4

4

Vbattery

3

5

LED - “POWER ON”

2

6

LED - “OVER TEMP”

1

 

1        2        3        4       5        6

LEGEND

  LED -  “Over Load”

  Toggle

  Ground

  Vbattery

  LED - “Power ON”

  LED - “Over Temp”

  

1.

2.

3.

4.

5.

6.

Figure 2 Remote Control RC-15A; Pintout of Modular Jack RJ-12 / RJ-25

1. As shown in Figure 2
2. Mirror image of Remote Control Jack due to crossed-over /rolled over connection of conductors.

Summary of Contents for RC-15A

Page 1: ...Remote Control for Inverter RC 15A Please read this manual before operating your RC 15A Remote Control Owner s Manual ...

Page 2: ... set with RJ 12 RJ 25 Modular Plugs 6P6C The conductors of the cable set have crossed over rolled over connec tions on the two RJ 12 RJ 25 plugs SECTION 3 LAYOUT OF CONTROLS INDICATIONS DIMENSIONAL DRAWING Fig 1 shows the layout of controls and indications and dimensional drawing LEGEND 1 ON OFF Push Button 2 RED LED Overload 3 RED LED Over Temp 4 GREEN LED Power 5 6P6C Modular Jack for connecting...

Page 3: ...he RJ 12 RJ 25 Modular Jack 5 at the back of the unit is given at Fig 2 below Fig 2 Remote Control RC 15A Pinout of Modular Jack RJ 12 RJ 25 The standard numbering system of the pins of a Modular Jack when looking into the Jack is from left to right As the conductors of the cable are cross connected rolled over the pinouts at the Modular Jack in the inverter will be a mirror image of the pinout of...

Page 4: ...nder heading LED Display above for information on the operating con ditions displayed Read the Owner s Manual of the inverter for troubleshooting abnormal conditions indicated by the LEDs No Load Current Draw As stated above the ON OFF Switch on the inverter is required to be in ON condition for the Remote to operate When the ON OFF switch on the Remote Control is turned ON all the circuitry insid...

Page 5: ...th crossed over rolled over connections Length 5M 16 5 ft Operating Temperature Range 0 C to 40 C 32 F to 104 F Dimensions L x W x D 90 x 64 4 x 27 9 mm 3 54 x 2 54 x 1 1 in Weight without cable Weight with cable 62 gm 174 gm 0 03 lb 0 08 lb NOTE Specifications are subject to change without notice SAMLEX AMERICA BATTERY CAR BATTERIES ...

Reviews: