before using this Remote Control, please follow the Safety Instructions given in 
the owner’s Manual for the inverter.

SECTION 2 | 

DESCRIPTION

RC-15A is a wired Remote Control that is compatible with the following series 
of Inverters:

• 

PST-600-12, PST-600-24

• 

PST-1000-12, PST-1000-24

It is used to switch oN and switch off the inverter from a remote location.  It 
also displays the operational status using colored LeDs. It is provided with 5 
metres / 16.5 feet of connecting cable set with RJ-12 / RJ-25 Modular Plugs 
(6P6C). The conductors of the cable set have crossed-over (rolled-over) connec-
tions on the two RJ-12 / RJ-25 plugs 

SECTION 3 | 

LAYOUT OF CONTROLS, INDICATIONS  

 

      & DIMENSIONAL DRAWING

fig. 1 shows the layout of controls and indications and dimensional drawing. 

  

LEGEND

1.  ON/OFF Push Button

2.  RED LED - “Overload”

3.  RED LED - “Over Temp”

4.  GREEN LED - “Power”

5.  6P6C Modular Jack for  connecting cable

     (16.5 feet / 5 M in length)

Front  View 

ON / OFF

MODEL RC-15A

    Pure 

Sine Wave

OVER

LOAD

OVER 

TEMP

POWER

64,4

90

Back View

45,6

45,6

9,4

9,4

18,05

50,7

21,25

32

32

6

R2

6

78

4

5

3

2

1

Overall Depth: 27.9

(NOTE: All dimensions in mm)

Fig. 1 Remote Control RC-15A -  
Layout and Dimensional Drawing

Summary of Contents for RC-15A

Page 1: ...Remote Control for Inverter RC 15A Please read this manual before operating your RC 15A Remote Control Owner s Manual ...

Page 2: ... set with RJ 12 RJ 25 Modular Plugs 6P6C The conductors of the cable set have crossed over rolled over connec tions on the two RJ 12 RJ 25 plugs SECTION 3 LAYOUT OF CONTROLS INDICATIONS DIMENSIONAL DRAWING Fig 1 shows the layout of controls and indications and dimensional drawing LEGEND 1 ON OFF Push Button 2 RED LED Overload 3 RED LED Over Temp 4 GREEN LED Power 5 6P6C Modular Jack for connecting...

Page 3: ...he RJ 12 RJ 25 Modular Jack 5 at the back of the unit is given at Fig 2 below Fig 2 Remote Control RC 15A Pinout of Modular Jack RJ 12 RJ 25 The standard numbering system of the pins of a Modular Jack when looking into the Jack is from left to right As the conductors of the cable are cross connected rolled over the pinouts at the Modular Jack in the inverter will be a mirror image of the pinout of...

Page 4: ...nder heading LED Display above for information on the operating con ditions displayed Read the Owner s Manual of the inverter for troubleshooting abnormal conditions indicated by the LEDs No Load Current Draw As stated above the ON OFF Switch on the inverter is required to be in ON condition for the Remote to operate When the ON OFF switch on the Remote Control is turned ON all the circuitry insid...

Page 5: ...th crossed over rolled over connections Length 5M 16 5 ft Operating Temperature Range 0 C to 40 C 32 F to 104 F Dimensions L x W x D 90 x 64 4 x 27 9 mm 3 54 x 2 54 x 1 1 in Weight without cable Weight with cable 62 gm 174 gm 0 03 lb 0 08 lb NOTE Specifications are subject to change without notice SAMLEX AMERICA BATTERY CAR BATTERIES ...

Reviews: