INSTALLATION
SETTING UP THE SCREEN ORIENTATION
It is mandatory to respect the flow
direction marked on the input and
output connections, such as “IN” and
“OUT”, otherwise the equipment will
not work. If due to the configuration
of your installation it is unavoidable
that the screen is reversed, you can
rotate it following the procedure
described below.
WARNING!:
Do this operation
before installing the device in
its location and with the power
source disconnected.
!
1.
Loosen the screws (1) and set the
front cover (2) aside. Be careful
that neither the electronic board
nor the wiring is
(Fig. 3).
2.
Loose the screws (3) that attach the
plastic housing (4)
(Fig. 4).
3.
Rotate 180 degrees the housing (4)
and attach it again using the screws
(3) loosen previously. Notice that only
3 of them are now needed
(Fig. 5).
4.
Place the front cover (2) in its rigth
position and fix it by means of the
screws (1)
(Fig. 6).
The following figures show the difference between the factory default
position and the position once that the screen is rotated. Notice the new
position of fluid connections.
FACTORY
POSITION
CONFIGURATION
ONCE ROTATED
Fig. 3
Fig. 4
Fig. 5
1
2
4
3
3
Fig. 6
2
1