![Samoa LARIUS VIKING Operating And Maintenance Manual Download Page 5](http://html1.mh-extra.com/html/samoa/larius-viking/larius-viking_operating-and-maintenance-manual_3965231005.webp)
www.larius.com
3
VIKING
ED. 03 - 09/2020 - Cod. 150163
B
C
VIKING
Supply
(single-phase, three-phase internal combustion supply, petrol-diesel)*
220V 50Hz / 110V 60Hz/ 380V 50Hz
Motor power mono-threephase
Internal combustion
4,5 kW
Max. Working pressure
210 bar
Max. Delivery
3+3 L/min
Material outlet
M16 x 1,5 (M)
Weight
50 Kg
Level of the sound pressure
≤ 75dB(A)
Length
(A) 1000 mm
Width
(B) 600 mm
Height
(C) 850 mm
*Available on request with special voltages
C
WORKING PRINCIPLE
The
LARIUS VIKING
unit is defined as an
“electric diaphragm
pump”
. An electric diaphragm pump is used for high pressure
paint spraying without air
(known as “airless”)
.
The pump is powered by an electric
(internal combustion)
motor
coupled with a cam shaft. The shaft acts on the hydraulic piston
as it pumps oil from the hydraulic case and sends the suction
diaphragm into fibrillation. When the diaphragm moves, it
creates a vacuum. The product is sucked up, pushed towards
the pump outlet and sent to the guns through the flexible hose.
A hydraulic valve on the hydraulic case head allows setting and
checking the pressure of the paint product at the pump outlet.
A second hydraulic safety valve to avoid over-pressure, ensures
total equipment reliability.
TECHNICAL DATA
A
B
PARTS OF THE PUMP IN CONTACT WITH THE MATERIAL:
Stainless Steel AISI 420B, PTFE, Aluminium.
Fig. 1C