WARNINGS

A

• Read this operator’s manual carefully before using the equipment.

• An improper use of this machine can cause injuries to people or things.

• Do not use this machine when under the influence of drugs or alcohol.

• Do not modify the equipment under any circumstances.

• Use products and solvents that are compatible with the various parts of the equipment, and read the manufacturer’s warnings carefully.

• See the Technical Details for the equipment given in the Manual.

• Check the equipment for worn parts once a day.  If any worn parts are found, replace them using ONLY original spare parts.

• Keep children and animals away from work area.

• Comply with all safety standards.

• It indicates an accident risk or serious damage to equipment if this warning is not followed.

FIRE AND EXPLOSION HAZARD

• Solvent and paint fumes in work area can ignite or explode.

• 

To help prevent fire and explosion:

   - Use equipment ONLY in well ventilated area.

   - Eliminate all ignition sources, such as pilot lights, cigarettes and plastic drop cloths (potential static arc).

   - Ground equipment and conductive objects.

   - Use only grounded hoses.

   -  Do not use trichloroethane, methylene chloride, other halogenated hydrocarbon solvents or fluids containing such solvents in 

 

pressurized aluminium equipment. Such use can cause serious chemical reaction and equipment rupture, and result in death, 

serious injury, and property damage.

   - Do not form connections or switch light switches on or off if the air contains inflammable fumes.

•  If electrical shocks or discharges are encountered the operation being carried out using the equipment 

must be stopped immediately

.

• Keep a fire extinguisher at hand in the immediate vicinity of the work area.
• It indicates wound and finger squashing risk due to movable parts in the equipment.

• Tenersi lontano dalle parti in movimento.

• Do not use the equipment without the proper protection.

• Before any inspection or maintenance of the equipment, carry out the decompression procedure explained in this manual, and prevent 

any risk of the equipment starting unexpectedly.

• Report any risk of chemical reaction or explosion if this warning has not been given.

•  (IF PROVIDED) There is a risk of injury or serious lesion related to contact with the jet from the spray gun. If this should occur, IMME

-

DIATELY contact a doctor, indicating the type of product injected.

• (IF PROVIDED) Do not spray before the guard has been placed over the nozzle and the trigger on the spray gun.

• (IF PROVIDED) Do not put your fingers in the spray gun nozzle.

• Once work has been completed, before carrying out any maintenance, complete the decompression procedure.

•  It indicates important recommendations about disposal and recycling process of products in accordance with the environmental 

regulations.

•  Mark any clamps attached to earth cables.

•  Use ONLY 3-wire extension cords and grounded electrical outlets.

•  Before starting work make sure that the electrical system is grounded and that it complies with safety standards.

• High-pressure fluid from gun, hose leaks, or ruptured components will pierce skin.

•  

To help prevent injection, always:

   - (IF PROVIDED) Engage trigger lock when not spraying.

   - (IF PROVIDED) Do not put your hand over the spray tip. Do not stop or deflect leaks with your hand, body or other.

   - (IF PROVIDED) Do not point gun at anyone or at any part of the body.

   - (IF PROVIDED) Never spray without tip guard.

   - Do pressure relief if you stop spraying or being servicing sprayer and before any maintenance operations.

   - Do not use components  rated less than sprayer Maximum Working Pressure.

   - Never allow children to use this unit

   - (IF PROVIDED) Brace yourself; gun may recoil when triggered.

If high pressure fluid pierces your skin, the injury might look like “just a cut”, but it is a serious wound!  

Get immediate medical attention.

• It is obligatory to wear suitable clothing as gloves, goggles and face shield.

• Wear clothing that complies with the safety standards in force in the country in which the equipment is used.

• Do not wear bracelets, earrings, rings, chains, or anything else that may hinder the operator’s work.

• Do not wear clothing with wide sleeves, scarves, ties, or any other piece of clothing that could get tangled up in moving parts of the 

equipment during the work, inspection, or maintenance cycles.

Summary of Contents for LARIUS VIKING

Page 1: ...w w w l a r i u s c o m ED 03 09 2020 Manuale Cod 150163 VIKING Elettric diaphragm pump OPERATING AND MAINTENANCE MANUAL EN...

Page 2: ...manual without prior notice This manual is to be considered as an English language translation of the original manual in Italian The manufacturer shall bear no responsibility for any damages or inconv...

Page 3: ...receive a range of support services enabling you to achieve the results desired quickly and professionally INDEX WARNINGS 2 WORKING PRINCIPLE 3 TECHNICAL DATA 3 DESCRIPTION OF THE EQUIPMENT 4 TRANSPO...

Page 4: ...carry out the decompression procedure explained in this manual and prevent any risk of the equipment starting unexpectedly Report any risk of chemical reaction or explosion if this warning has not be...

Page 5: ...for high pressure paint spraying without air known as airless The pump is powered by an electric internal combustion motor coupled with a cam shaft The shaft acts on the hydraulic piston as it pumps o...

Page 6: ...12 3 7 4 5 6 4 8 8 Pos Description 1 Carriage 2 Electric motor 3 High pressure manometer 4 Setting valve 5 Hydraulic oil filling cap 6 Hydraulic body Pos Description 7 Complete colour body 8 Suction...

Page 7: ...OUT THE USE OF SAFETY DEVICES FOR THEIR OWN SAFETY AND ABOUTTHEGENERALRULESFORACCIDENTPREVENTION INCOMPLIANCEWITHINTERNATIONALREGULATIONSAND WITH THE LAWS OF THE COUNTRY WHERE THE PLANT IS USED THE BE...

Page 8: ...uctinthehose can create static electricity through discharges andsparks Itissuggestedtoearththeequipment The pump is earthed through the earth cable of the supply The gun is earthed through the high p...

Page 9: ...ON OF THE TOOLING TO THE POWER SUPPLY Check the ON OFF switch H2 is on the OFF position 0 before connecting the cable to the mains Place the pressure control knob H3 on the MIN position turn countercl...

Page 10: ...solvent As the pump idles press the ON OFF switch H6 su OFF 0 on the position OFF 0 to stop the tooling WORKING START OF THE PAINTING OPERATIONS Use the tooling after performing all the SETTING UP op...

Page 11: ...l bands coats Keep a safety and constant distance between the gun and the support to be painted and also keep yourselves perpendicular to it CLEANING AT THE END OF THE WORK Reduce pressure to the mini...

Page 12: ...he pump in the following way Remove the suction hose fitting and release the valve by inserting a rigid rod K1 with a diameter of no more than 15 mm AGIP DICREA 150 type hidraulic oil REPLACING HYDRAU...

Page 13: ...ent does not suck the product Suction filter clogged Clean or replace it Suction filter too fine Replace it with a larger mesh filter with very dense products remove the filter The equipment sucks air...

Page 14: ...oosen very slowly the fitting of connection from the flexible hose to the gun Clean or replace the flexible hose and the nozzle CORRECT PROCEDURE OF DECOMPRESSION Insert the gun clamp N1 Move the ON O...

Page 15: ...larius com 13 VIKING ED 03 09 2020 Cod 150163 SUCTION SYSTEMS 1 3 2 4 O Pos Code Description 85009 Suction systems 1 85010 Suction tube 2 35003 Recirculation tube 3 18096 Spring 4 85012 Filter of suct...

Page 16: ...m 14 VIKING ED 03 09 2020 Cod 150163 COMPLETE HYDRAULIC BODY 52 7 6 5 4 3 53 51 50 48 47 46 49 19 20 18 17 16 15 13 11 14 12 10 9 8 25 21 22 23 2 24 26 27 28 29 30 1 31 33 34 32 35 37 39 41 45 36 38 4...

Page 17: ...12461 Oil filter body 25 32108 Oil cup 3 8 26 32041 Sleeve nut 27 32022 Spring Pos Code Description 28 32021 Washer 29 32020 Elastic ring 30 32019 Piston 31 82005 Oil cup 32 31128 High temperature 28...

Page 18: ...www larius com 16 VIKING ED 03 09 2020 Cod 150163 COMPLETE COLOUR BODY 1 25 33 32 31 28 27 26 29 30 16 19 17 18 20 18 21 22 23 24 4 15 14 13 12 11 10 9 8 7 6 3 2 5 Q...

Page 19: ...guide 10 33022 Spring 11 33023 6 3 washer 12 33024 Selflocking nut 13 33025 Inlet liner 14 33005 10 SCHNORR washer 15 33004 10x55 TCE screw 16 33016 Complete return tap Pos Code Description 17 33015...

Page 20: ...Pos Code Description 1 81001 Electric motor 220V 50Hz 1 81002 Electric motor 380V 50Hz three phase 1 81003 Electric motor 110V 60Hz 2 16071 Electic box 3 86001 Condenser 4 81012 Stud bolt 5 81033 Wash...

Page 21: ...2004 Screw 4 31116 Motor pinion 5 31115 Washer 6 69011 Screw 7 4019 Screw 8 32028 Washer Pos Code Description 9 31111 Plate 10 31110 Crown gear 11 31109 Bearing 12 31128 Corteco 13 54003 Washer 14 311...

Page 22: ...White 60M 11019 Red 200M FILTERS Art Description 270 Filter 100 MESH 271 Filter 60 MESH FILTERS Art Description 85014 Filter 40 MESH 37215 Filter 40 MESH inox 85012 Filter 20 MESH 37216 Filter 20 MES...

Page 23: ...t Nozzles code SFC07 20 SFC21 20 SFC31 60 SFC07 40 SFC21 40 SFC31 80 SFC09 20 SFC21 60 SFC33 40 SFC09 40 SFC23 20 SFC33 60 SFC11 20 SFC23 40 SFC33 80 SFC11 40 SFC23 60 SFC39 40 SFC13 20 SFC25 20 SFC39...

Page 24: ...24 cm PLA 16x1 5 BASE SUPER FAST CLEAN Art Description K11421 130 cm K11426 180 cm K11431 24 cm TELESCOPIC PAINT ROLLER Art Description 16780 complete with n 1 Roller with extra long fiber n 1 Roller...

Page 25: ...www larius com 23 VIKING ED 03 09 2020 Cod 150163 AIRLESS DIAPHRAGM PUMPS DALI Rif 18900 MIRO Rif 21500 GIOTTO Rif 12450...

Page 26: ...I n t e n t i o n a l l y b l a n k p a g e...

Page 27: ...September 2020 Location Date complies with the directives EC Directive 2006 42 Machinery Directive EU Directive 2014 30 Electromagnetic Compatibility EMC EU Directive 2014 35 Low Voltage LVD furtherm...

Page 28: ...LARIUS srl Via Antonio Stoppani 21 23801 Calolziocorte LC ITALY TEL 39 0341 621152 Fax 39 0341 621243 larius larius com www larius com...

Reviews: