www.larius.com
15
L200 - L201
REV.
01 - 01/2020 - Cod. 150084
FIRE OR EXPLOSION HAZARD
Static electricity is created by the flow of fluid through the pump
and hose. If every part of the equipment is not properly grounded,
sparking may occur, and the system may become hazardous.
Sparks may also occur when plugging in or unplugging a power
supply cord. Sparks can ignite fumes from solvents and the fluid
being dispensed, dust particles and other flammable substances,
whether you are pumping indoors or outdoors, and cause a fire
or explosion, serious injury, and property damage.
GROUNDING
To reduce the risk of static sparking, ground the pump and
all other equipment used or located in the dispensing area.
Check your local electrical code for detailed grounding instructions
for your area and type of equipment and be sure to ground all of
the following equipment.
• Pump: ground the pump by connecting a grounding wire from
the pump’s grounding lug to a true earth ground.
• Air compressor or hydraulic power supply: ground according to
local code and manufacturer’s recommendations.
• Fluid hoses: use only grounded hoses with a maximum of 150
mt. Combined hose length to ensure grounding continuity.
Refer to hose grounding continuity, above.
• Flo-gun: obtain grounding through connection a properly
grounded fluid hose and pump.
• Fluid supply container: according to local code.
• All solvent pails used when flushing: according to local code.
Use only metal pails. Do not place the pail on a non-conductive
surface, such as paper or cardboard, which interrupts the
grounding continuity.
Moving parts can pinch or amputate your fingers or other body
parts. Keep clear of moving parts when starting or operating
your system.
Before checking or servicing the gun, pump, or any other system
component follow the PRESSURE DISCHARGING PROCEDURE
to prevent the pump from starting accidentally.
Do not plug in or unplug any power supply cords
in the dispensing area when there is any chance
of igniting fumes still in the air.
If you experience any static sparking or feel even
a slight shock while using this equipment, STOP
DISPENSING IMMEDIATELY. Check for proper
grounding of the entire system. Do not use the
system again until the cause of the problem is
identified and corrected.
Before flushing, be sure the entire system and
flushing pails are properly grounded. Refer to
GROUNDING, above. Always use the lowest
possible fluid pressure, and maintain firm
metal-to-metal contact between the gun and
grounded metal pail during flushing to reduce
the risk of fluid injection injury, static sparking
and splashing.
CONDITIONS OF GUARANTEE
N
The conditions of guarantee do not apply in the
following situations:
- improper washing and cleaning of components
causing malfunction, wear or damage to the
equipment or any of its parts;
- improper use of the equipment;
- use that does not conform with applicable
national legislation;
- incorrect or faulty installation;
- modifications, interventions and maintenance
that have not been authorised by the
manufacturer;
- use of non-original spare parts or parts that do
not correspond to the specific model;
- total or partial non-compliance with the
instructions provided.
L
MOVING PARTS HAZARD
M