LARIUS GHIBLI MIX 2K
CONTROL
Delay start cycle control counter:
Waiting time
before the linear encoder conditions check cycle
starts.
Pause control counters:
Repeat time of the control
described above.
EV opening time for control:
Maintained valve
opening time for counting impulses for the control
described above.
Pulse level for counters alarm:
Number of impul-
ses to be exceeded during valve opening.
Quantity of material to be regenerated:
Amount
of product to be counted for bleeding after pot
life operation or for loading paint. This relates to
the amount contained in the flexible hose that
connects the spray gun to the static mixer. This
amount depends on the length of the hose and on
its internal diameter.
Pulses per litre:
Value which is used to transform
impulses counted in litres, displayed on the con-
sumptions page.
Flux Washing Solv 1
ON ENABLED - OFF DISABLED
Enabling of flow meter control on SOLV 1 circuit.
Flux Washing Solv 2
ON ENABLED - OFF DISABLED
Enabling of flow meter control on SOLV 2 circuit
Pressure switch A:
Enabling the minimum product
pressure control on circuit A
EV Air Washing:
Enabling blowing air after SOLV
1 cycle
EV Solv. Washing 2:
Enabling SOLV 2 washing
On this page, enter the values controlling the action
thresholds relative to counting system faults on the
linear encoders.
On this page, you can enable the machine control
systems and the mode and type of washing de-
pending on how the machine is configured and built.
CONTROL ADVANCED SETUP
Impulse threshold for leakage alarm
circuit A - circuit B
It is possible to set the number of impulses to be exceeded for certain
leakage alarms on the relative pump or on the leakage of the dosing
valve or on the recirculation valve of circuit A or B.
HOW IT WORKS: at the closing of the EvA or EvB valve, if the respective
pump moves and the wire encoder exceeds the number of impulses
set as the threshold, the machine recognises that the product is leaking
or there is a loss of retention that can be searched for in:
- Loss of retention of the dosing valve ball/sleeve
- pump with worn gasket seals or sealing balls
- Recirculation tap with leaks