![Samoa LARIUS GHIBLI MIX 2K Operating And Maintenance Manual Download Page 16](http://html1.mh-extra.com/html/samoa/larius-ghibli-mix-2k/larius-ghibli-mix-2k_operating-and-maintenance-manual_3745205016.webp)
J7
www.larius.com
16
ED. 04 - 04/2021 - Cod. 150183
LARIUS GHIBLI MIX 2K
DO NOT use thread pastes upon the connections.
It is recommended to use the tubes which have been
supplied along with the machine.
NEVER use a damaged or repaired flexible tube.
Make sure that the system is properly grounded.
Use an electrical plug which guarantees the proper
grounding of the system.
The machine requires a 220V alternating current
power supply.
Should anyone use an extension cable between
the tooling and the socket, it must have the same
characteristics as the cable supplied (
minimum
diameter of the wire 4 mm
2
) with a maximum len-
gth of 50 mt. Higher lengths and lower diameters
can provoke excessive voltage falls and also an
anomalous working of the equipment.
CHECK ON POWER SUPPLY
Connect the recirculation lines:
• Product A (
J4
)
• Catalyst B (
J5
)
• Solvent W (
J6
)
Connect the mixed product supply spray gun hose (
J7
)