The table below provides the meaning of the symbols used in this manual in relation to using, earthing, operating, maintaining, and 
repairing of this equipment.

WARNINGS

• Read this operator’s manual carefully before using the equipment.

• An improper use of this machine can cause injuries to people or things.

• Do not use this machine when under the influence of drugs or alcohol.

• Do not modify the equipment under any circumstances.

• Use products and solvents that are compatible with the various parts of the equipment, and read the manufacturer’s warnings carefully.

• See the Technical Details for the equipment given in the Manual.

• Check the equipment for worn parts once a day.  If any worn parts are found, replace them using ONLY original spare parts.

• Keep children and animals away from work area.

• Comply with all safety standards.

• It indicates an accident risk or serious damage to equipment if this warning is not followed.

FIRE AND EXPLOSION HAZARD

• Solvent and paint fumes in work area can ignite or explode.

• 

To help prevent fire and explosion:

   - Use equipment ONLY in well ventilated area.

   - Eliminate all ignition sources, such as pilot lights, cigarettes and plastic drop cloths (potential static arc).

   - Ground equipment and conductive objects.

   - Use only grounded hoses.

   -  Do not use trichloroethane, methylene chloride, other halogenated hydrocarbon solvents or fluids containing such solvents in 

 

pressurized aluminium equipment. Such use can cause serious chemical reaction and equipment rupture, and result in death, 

serious injury, and property damage.

   - Do not form connections or switch light switches on or off if the air contains inflammable fumes.

•  If electrical shocks or discharges are encountered the operation being carried out using the equipment 

must be stopped immediately

.

• Keep a fire extinguisher at hand in the immediate vicinity of the work area.
• It indicates wound and finger squashing risk due to movable parts in the equipment.

• Tenersi lontano dalle parti in movimento.

• Do not use the equipment without the proper protection.

• Before any inspection or maintenance of the equipment, carry out the decompression procedure explained in this manual, and prevent 

any risk of the equipment starting unexpectedly.

• Report any risk of chemical reaction or explosion if this warning has not been given.

•  (IF PROVIDED) There is a risk of injury or serious lesion related to contact with the jet from the spray gun. If this should occur, IMME

-

DIATELY contact a doctor, indicating the type of product injected.

• (IF PROVIDED) Do not spray before the guard has been placed over the nozzle and the trigger on the spray gun.

• (IF PROVIDED) Do not put your fingers in the spray gun nozzle.

• Once work has been completed, before carrying out any maintenance, complete the decompression procedure.

•  It indicates important recommendations about disposal and recycling process of products in accordance with the environmental 

regulations.

•  Mark any clamps attached to earth cables.

•  Use ONLY 3-wire extension cords and grounded electrical outlets.

•  Before starting work make sure that the electrical system is grounded and that it complies with safety standards.

• High-pressure fluid from gun, hose leaks, or ruptured components will pierce skin.

•  

To help prevent injection, always:

   - (IF PROVIDED) Engage trigger lock when not spraying.

   - (IF PROVIDED) Do not put your hand over the spray tip. Do not stop or deflect leaks with your hand, body or other.

   - (IF PROVIDED) Do not point gun at anyone or at any part of the body.

   - (IF PROVIDED) Never spray without tip guard.

   - Do pressure relief if you stop spraying or being servicing sprayer and before any maintenance operations.

   - Do not use components  rated less than sprayer Maximum Working Pressure.

   - Never allow children to use this unit

   - (IF PROVIDED) Brace yourself; gun may recoil when triggered.

If high pressure fluid pierces your skin, the injury might look like “just a cut”, but it is a serious wound!  

Get immediate medical attention.

• It is obligatory to wear suitable clothing as gloves, goggles and face shield.

• Wear clothing that complies with the safety standards in force in the country in which the equipment is used.

• Do not wear bracelets, earrings, rings, chains, or anything else that may hinder the operator’s work.

• Do not wear clothing with wide sleeves, scarves, ties, or any other piece of clothing that could get tangled up in moving parts of the 

equipment during the work, inspection, or maintenance cycles.

Summary of Contents for Larius 3700

Page 1: ...01 09 2020 Manuale Cod 150169 II 2 G c IIB T4 OPERATING AND MAINTENANCE MANUAL EN P31 2 1 Pneumatic tranfer pump Stubby version Cod 3710 Stainless steel stubby Cod 3715 Long version Cod 3700 Stainless...

Page 2: ...manual without prior notice This manual is to be considered as an English language translation of the original manual in Italian The manufacturer shall bear no responsibility for any damages or inconv...

Page 3: ...eceive a range of support services enabling you to achieve the results desired quickly and professionally INDEX WARNINGS 2 WORKING PRINCIPLE 3 TECHNICAL DATA 3 DESCRIPTION OF THE EQUIPMENT 4 TRANSPORT...

Page 4: ...carry out the decompression procedure explained in this manual and prevent any risk of the equipment starting unexpectedly Report any risk of chemical reaction or explosion if this warning has not be...

Page 5: ...re 35 bar Air inlet 1 4 BSPP A A D E B D B C C WORKING PRINCIPLE TECHNICAL DATA P312 1pumpisapneumaticpumpdesignedforthetransferoflow vscosityproducts antifreeze solvents lacquers lightadhesives pump...

Page 6: ...Pos Description 1 Pneumatic motor group 2 Manometer 3 Outlet material 4 Air inlet Pos Description 5 Grounding cable 6 Pumping material tube 7 Material inlet 1 1 3 3 5 5 4 4 6 6 7 7 2 2 DESCRIPTION OF...

Page 7: ...ABOUT ALL THOSE RISKS STEMMING FROM ACCIDENTS ABOUT THE USE OF SAFETY DEVICES FOR THEIR OWN SAFETY AND ABOUTTHEGENERALRULESFORACCIDENTPREVENTION INCOMPLIANCEWITHINTERNATIONALREGULATIONSAND WITH THE L...

Page 8: ...use paints or solvents containing Halogen Hydrocarbons as the Methylene Chloride If these products come into contact with aluminium parts can provoke dangerous chemical reactions with risk of corrosio...

Page 9: ...ible hose etc before using the equipment Always avoid working the machine with the vacuum pump without liquid to suct a pump in this situation starts to accelerate the stroke till to reach an excessiv...

Page 10: ...ius com 8 P31 2 1 REV 01 09 2020 Cod 150169 L Fig 1L 1 2 3 4 5 6 7 3 8 9 10 11 16 17 18 19 20 12 13 14 15 ATTENTION always indicate code and quantity of each requested detail COMPLETE PNEUMATIC MOTOR...

Page 11: ...Atex plate 1 7 10112 Stainless steel label 1 8 3621 Complete motor piston 1 9 3312 Washer 1 10 3313 Lower piston spring 1 11 3638 Plug 1 12 3624 Piston stem 1 13 3634 Spring 1 14 3635 Complete silince...

Page 12: ...A LUNGA CORTA 1 2 3 4 5 6 7 8 9 10a 11 12 11 12 13 7 7 8 8 14 15 16 17 18 19 20 21 22 23 24 25 26 17 17 27 28 29 30 31 22 22 32 33 34 36 33 35 31 10b S H O R T L O N G LONG SHORT ATTENTION always indi...

Page 13: ...ss steel 1 Pos Code Description Q ty 20 3729 Tie rod long version 1 3856 Tie rod stainless steel long version 1 21 3859 Piston upper section stainless steel 1 22 95021 Ball 7 8 2 98053 Ball 7 8 stainl...

Page 14: ...1 2 1 REV 01 09 2020 Cod 150169 N Fig 1N Fig 2N Code Description 3710 P31 short version 3715 P31stainlesssteelshort version Code Description 3700 P31 long version 3705 P31stainlesssteellongversion COM...

Page 15: ...www larius com 13 P31 2 1 REV 01 09 2020 Cod 150169...

Page 16: ...t the product Company Signature Calolziocorte 16 September 2020 Location Date complies with the directives EC Directive 2006 42 Machinery Directive furthermore to the harmonized standards UNI EN ISO 1...

Page 17: ......

Page 18: ...LARIUS srl Via Antonio Stoppani 21 23801 Calolziocorte LC ITALY TEL 39 0341 621152 Fax 39 0341 621243 larius larius com www larius com...

Reviews: