background image

4

838 841 R. 12/18

 SAMOA Industrial, S.A. · Pol. Ind. Porceyo,  I-14 · Camino del Fontán, 831 · 33392 -  Gijón - Spain · Tel.: +34 985 381 488 · www.samoaindustrial.com

EN

2018_12_14-12:00

in  order  to  install  the  wireless  kit  381909  (if  not  already 
installed from factory), follow the next steps:

1. Turn off and disconnect the power source of the unit.
2. Remove the plastic cover (1) unscrewing the screws (2).
3. insert the wireless PCB kit (3) in the socket as it is shown 

in figure 8. Pay attention to PCB orientation.

4.  mount the new provided cover (4) with the two screws (2).
5. Turn on and/or connect again the unit power source.

InStALLAtIon And coMMISSIonInG

WARNING: Do not install or remove the wireless 
kit  while  the  unit  remains  powered.  This  may 
result in a damaged unit or personal injury. Risk of 
electrical shock!

!

wiReless KiT insTallaTiOn 

(OPTiOnal)

at this point, the unit is already prepared to be paired with 
a u-Vision or u- unit. Consult the u-Vision manual 
for further information.

seTTing The lOCal PaRameTeRs Of The uniT

Before  the  unit  can  operate,  a  few  configuration  steps 
must be accomplished:
1. Connect the power to the unit. it will appear briefly on 

the display the current firmware installed and then the 
hose reel address is shown (by default “001” ).

2. Press and hold f1 and f2 buttons until it is shown “seT" 

in the display.

3. The display shows the message “a” (address) followed 

by a number that increases progressively from 001. This 
number  is  the  hose  reel  number  linked  to  the  unit. 
Once that the desired number is shown, press briefly f2 
button.
nOTe: if it is needed to restart the hose reel number to 
“001" , press briefly f1 button.

4. now the unit shows the message “eol” (end of line), 

followed  by  “0”  or  “1”.  This  parameter  allows  to 
indicate whether the unit is end of line in the Can Bus 
(1)  or  it  is  an  intermediate  unit  (0).  Change  the 
adjustment pressing the f1 button briefly and press f2 
button to confirm.

NOTE: if the unit is configured as end of line, the end 
of  line  blue  led  lights  up  in  order  to  ease  the 
identification of bus endings. 

5. in the next screen the display shows the message “Dir.” 

followed by an animated bars graphic. This parameter 
allows to set the fluid flow direction through the unit. 
Press  f1  button  to  set  flow  direction  so  that  the 
animated bars movement matches the fluid flow in the 
unit. Press f2 button to confirm.

6. having reached this point, the unit stores in its memory 

all  the  parameters  introduced  and  it  is  restarted  with 
these new parameters.

NOTE:  in  the  case  that  the  unit  is  restarted  before 
reaching this last step (due to a power loss or whatever 
reason), the parameters introduced will not be stored in 
the unit.

1

Fig. 7

2

3

4

2

Summary of Contents for 381 513

Page 1: ...ceyo I 14 Camino del Font n 831 33392 Gij n Spain Tel 34 985 381 488 www samoaindustrial com 2018_12_14 12 00 Part No C d 381 513 383 514 U meter U meter 2 U meter U meter 8 EN ES Parts and technical...

Page 2: ...lid particles carried by the fluid is recommended the installation of a 200 mesh strainer at the unit inlet It is advised to install the solenoid valve associated to the U Meter at the unit inlet Do n...

Page 3: ...BUS cable to the 5 pole male plug 951982 according to the scheme shown in figure 7 NOTE Depending on installation layout it may be possible that in one of the 5 pole plugs the power wires red black m...

Page 4: ...wn by default 001 2 Press and hold F1 and F2 buttons until it is shown SET in the display 3 The display shows the message A address followed by a number that increases progressively from 001 This numb...

Page 5: ...or Consult the calibration procedure of the system Flow exceeding flowmeter range The solenoid valve does not open Check the indicator leds If CAN BUS led green is on and S V ON led red is blinking th...

Page 6: ...in depending on fluid viscosity and temperature Viscosity range 8 to 2000 cSt Working temperature 10 C to 60 C 14 to 140 F Pressure loss at maximum flow 3 bar Precision 0 5 after calibration Pulse rat...

Page 7: ...stic cover for 2 pole connector 1 SPARE PARTS AND ACCESORIES Disposal information The symbol above means that according to local laws and regulations your product and or its battery must be disposed o...

Page 8: ...comienda la instalaci n de un filtro de al menos mesh 40 a la entrada del equipo Se aconseja instalar la electrov lvula asociada al equipo a la entrada de la misma y no a la salida para que el equipo...

Page 9: ...s al conector macho enchufable de 5 polos 951892 de acuerdo al esquema representado en la figura 6 NOTA en funci n de la topolog a de la instalaci n es posible que en uno de los conectores enchufables...

Page 10: ...ione simult neamente las teclas F1 y F2 del frontal de la unidad hasta que el display muestre el mensaje Set 3 En este punto el display mostrar el mensaje A address seguido de un n mero que se ir incr...

Page 11: ...o Consultar el proceso de calibra ci n del sistema Caudal fuera del campo nominal de aplicaci n del medidor La electrov lvula no abre Comprobar leds de estado Si la luz CAN BUS verde est encendida y l...

Page 12: ...8 a 2000 cSt Temperatura de operaci n 10 C a 60 C P rdida de presi n al caudal m ximo 3 bar Precisi n 0 5 una vez calibrado Ratio de pulsos 328 ppl Alimentaci n 24V AC DC 50 60 Hz Compatibilidad de e...

Page 13: ...r de 2 polos 1 C DIGOS DE REPUESTOS Y ACCESORIOS INFORMACI N SOBRE DESECHO DE RESIDUOS El s mbolo anterior indica que de acuerdo con las normativas locales su producto y o su bater a deber n desechars...

Page 14: ...2018_12_14 12 00 14 838 841 R 12 18 SAMOA Industrial S A Pol Ind Porceyo I 14 Camino del Font n 831 33392 Gij n Spain Tel 34 985 381 488 www samoaindustrial com Notes Notas...

Page 15: ...15 R 12 18 838 841 SAMOA Industrial S A Pol Ind Porceyo I 14 Camino del Font n 831 33392 Gij n Spain Tel 34 985 381 488 www samoaindustrial com 2018_12_14 12 00 Notes Notas...

Page 16: ...tive s 2014 30 EC EN SAMOA INDUSTRIAL S A Pol Ind Porceyo I 14 Camino del Font n 831 33392 Gij n Espa a declara que el los producto s 381 513 383 514 cumple n con la s Directiva s de la Uni n Europea...