HANDLING
The meter has two recorders, the upper recorder shows
the total meter and the lower recorder shows the partial
meter. Each unit of dispensed volume, increases both the
partial and the total recorders.
The total recorder shows the dispensed total fluid volume
dispensed since the meter was put into operation for first
time. The total recorder can’t be resettable. To reset the
partial recorder, press the reset button.
Both the total and the partial recorders are reset when
they reach the value of 99999,9 and 999,9 respectively.
Do not exceed the maximum unit working pressure
detailed in the technical specifications
Due to the the single verification during the manufacturing
process, it’s normal that the total recorder is not set to
zero.
CALIBRATION
TROUBLESHOOTING
The meter do not allows calibration. If an error in the
measure is detected, check that the operating flow is
within the operating range. Also, check that the fluid
dispensed is one of those indicated as compatible with the
meter.
Symptom
Possible cause
Solution
The meter is inaccurate
A fluid with very high or very low
viscosity is being used.
The meter does not allow calibration;
try adjusting the operating conditions
within the operating range of the
meter.
Very high or low fluid temperature
The meter is working outside its
field of application (see technical
specifications).
Reduced flow
Dirt in the measuring chamber.
Inform technical support.
Blocked or dirty filter.
Clean the filter.
The meter does not count
Faulty recorder.
Inform technical support.