2  Connection (To be carried out when voltage is off ) 

2.1 Strip the power supply cable on 35 to 40 mm (depending on whether it is flexible or rigid), then strip each conductor 

on 7 mm. 

2.2  Insert the power supply cable through the cable gland of the mobile flange 

  without tightening it. 

2.3  Connect both live and neutral connectors to the relevant terminals of the block (L and N). 
2.4  Connect the earth on the relevant central terminal of the block (

). 

2.5  Lock the closing cover of the connector and lock it with the provided screws. 

Important: 

-

 

The mains supply of the device must be taken downstream from the protection device and upstream from the control 
device for the normal lighting of the room where it is installed. 

-

 

To ensure the required tightness, use a round supply cable, for example a U1000 R2V or H 07 RNF 3G1.5² in those 
cases (the contractor is responsible for the choice of the cable). 

Note: 

-

 

As the cable gland supplied with the luminaire is certified  

‘Ex eb‘, “

Ex tb”

II 2G  

 II 2D, it is strictly forbidden 

to replace it with another one. 

-

 

In order to provide the tightness required, the cable gland used is designed for one and only one round cable with 
an external diameter included between 10 and 12 mm. For the choice of the cable (type and nominal section), in any 
situation, the relevant installation documents shall be complied with. 

Maintenance (To be carried out by trained and duly approved staff) 

The user should make sure that the conditions of use and maintenance are complied with (cleaning, replacement of 
lamps, replacement with appropriate fuses, tightening of the various components, etc.). 

Sammode cannot be held responsible should these instructions not be complied with. 
 

1 Cleaning: 

In order  to avoid deposits and accumulations of dust on the  surface  of the luminaires,  the user should clean them 
regularly. The most appropriate way to clean them is the use a lukewarm, soapy water solution or water with a soft 
household cleaning product, using a soft cloth or sponge to remove the dirt and dust. All the surfaces must then be 
rinsed with cold water and dried immediately with a soft cloth to avoid water drop traces. 
Do not use any abrasive cleaning agents or cleaning products with high alkaline concentration. 
Never scratch the tubular housing with a scraper, a razor blade or any other sharp tools. 
For version II 2G: POTENTIAL ELECTROSTATIC CHARGING HAZARD 

 use only wet cloth or sponge 

 

2 Led module replacement: 

Led modules have a lifetime of 50000h, for a normal use. Beyond that period and at the latest if it proves to be faulty, 
the led module should be replaced. 
 

3 Driver replacement: 

The drivers have a lifetime of 50000h, for a normal use. Beyond that period and at the latest if it proves to be faulty, the 
driver should be replaced. 
 

4 Repair of the unit: 

The repair of the unit cannot be undertaken without SAMMODE’s prior consent in writing

 

Special requirements for a safety use 

For shocks, for glass version, the user will have to take into account the fact that the light fitting can bear only a weak 
mechanical risk (2J). The user will have to take into account the fact that the light fitting needs to be installed in an 
area protected against shock or with an additional protection.

 

 

 

Summary of Contents for Sabatier LumLed 1 SAB133 12H

Page 1: ...A 24 rue des Amandiers F 75020 Paris 1 12 Notice SABATIER V20190918 V20190918 SABATIER LumLed1 Notice d instructions User s guide Gebrauchsanweisungen II 2G Ex eb mb IIC T4 II 2D Ex tb IIIC T65 C Db I...

Page 2: ...Tamb 20 C 35 C SAB133 25H AVERTISSEMENTS WARNINGS ACHTUNG NE PAS OUVRIR SOUS TENSION NE PAS OUVRIR SI UNE ATMOSPHERE EXPLOSIVE EST PRESENTE Pour les corps PO et POME DANGER POTENTIEL DE CHARGES LECTRO...

Page 3: ...me d un nuage de poussi res combustibles dans l air est susceptible de se former occasionnellement en service normal selon EN 60079 14 zone 1 Emplacement dans lequel une atmosph re explosive sous form...

Page 4: ...d utilisation et d entretien sont respect es nettoyage changement des lampes remplacement des fusibles corrects serrage des diff rents l ments Le non respect de celles ci ne saurait engager la respons...

Page 5: ...tive la limitation de l utilisation de certaines substances dangereuses dans les quipements lectriques et lectroniques Directive 2012 19 UE relative aux d chets d quipements lectriques et lectroniques...

Page 6: ...EN 60079 14 Area 1 Location where an explosive atmosphere taking the form of a combustible gas cloud in the air is liable to occasionally gather under normal operating conditions according to EN 60079...

Page 7: ...maintenance are complied with cleaning replacement of lamps replacement with appropriate fuses tightening of the various components etc Sammode cannot be held responsible should these instructions not...

Page 8: ...trictions on the use of certain hazardous substances in Electrical and Electronic Equipment Directive 2012 19 EU and Known as WEEE Waste Electrical and Electronic Equipment ATEX Directive 2014 34 EU T...

Page 9: ...ine explosionsgef hrdete Atmosph re in der Form einer brennbaren Gaswolke in der Luft unter normalen Bedingungen eventuell ergeben kann nach EN 60079 10 F r die Bestimmung und Festlegung dieser Zonen...

Page 10: ...brauchs und Wartungsbedingungen beachtet werden Reinigung Ersetzen der Leuchtmittel Ersetzen der durchgebrannten Sicherung mit geeigneten Sicherungen Anziehen der verschiedenen Komponente usw Bei Nich...

Page 11: ...UE die sogenannte RoHS ber die Beschr nkung der Verwendung bestimmter gef hrlicher Stoffe in Elektro und Elektronikger ten der Richtlinie 2012 19 UE die sogenannte WEEE ber Elektro und Elektronikger...

Page 12: ...tions for the marking of the equipment English labels are provided with the luminaire Stick them on the French version Angaben f r die Markierung der Leuchte Die deutschen Etiketten werden mit den Leu...

Reviews: