Item
Description
Data
Comment
Protection
Anti-Islanding
Yes
DC Input Over Voltage
and Under Voltage
Yes
Input Over Current
Yes
AC Output Over Voltage
and Under Voltage
Yes
Output Over Current
Yes
DC Ground Fault Detect
and Interruption
Yes
Current Limiting
Yes
Power Limiting
Yes
Frequency Decrease
and Frequency Increase
Yes
Internal Shutdown
Internal protection tripping relay
Surge immunity
IEEE C62.41.2 : 2002
Location category C Low
Power Control
Input Power Control
Maximum Power Point Tracking (MPPT)
System Control
Automatic grid AC voltage sensing
Automatic recovery after grid failure
Control Type
Current control, microprocessor assisted
output regulation
Control Hardware Platform
DSP
Power Hardware Platform
IGBT-based inverter
External Fault Test
Short Circuit
Yes
Features
Heat Dissipation
Convection
Display
LCD Display
Environmental
Operating Temperature
-20
℃~50℃
Storage Temperature
-20
℃~50℃
Relative Humidity
0~95% Non-condensing
Altitude
10,000ft (3000m)
Audible Note
< 45 dB at 1m
Size
Dimensions (mm)
L382*W175*H398
Weight (kg)
15kg
Product Regulations
Safety
UL1741-2005
IEEE 1547.1-2005
EMC
FCC Part15 Class B