TECHNICAL DATA

BGW

-

200

ELECTRICAL

Input voltage range

6 … 35 V

Maximum continuous output current (@25 °C)

200 A

Peak current (@25 °C)

1200 A (±0.7 sec)

Voltage drop

50 mV @ 200 A

Current Output active

3.2 mA

Consumption Output inactive

3.2 mA

Voltage accuracy

2%

Current accuracy

10%

Maximum status/alarm output load

100 mA

INPUT & OUTPUT CONNECTOIN

Minimum wire diameter

50 mm

2

Bolt size

M8

Cable lugs

Cable lugs must match the cable diameter used.

FASTON CONNECTIONS

Minimum wire diameter

1.5 mm

2

Faston plug

6.3 mm

MECHANICAL

Mounting hole (Ø)

4.5 mm

Distance between mounting holes (centre to centre) ± 1 mm

100 mm

Weight

295 g

Dimensions (H*W*L) ± 1 mm

39*76*111 mm

IP Code

IP66

Housing material

PU552

Housing colour

Black

Cooling concept

Convection and conduction.

GENERAL

Operational ambient temperature

-10 °C  ... +40 °C

Storage temperature

-25 °C  ... +85 °C

Operational air humidity

Up to 95%, non-condensing.

Galvanic insulation

No

Remote contact switch-off

Yes

PROTECTION

Overcurrent/Short circuit

Yes (after 1 minute restart).

Overheating, shutdown

Above 85 °C (after 1 minute restart).

Polarity protection

Yes, with fuse in the minus (-) line.

Summary of Contents for BGW-200

Page 1: ...Overcurrent protection The current through the BGW is constantly monitored If an excessive current flows through the BGW for too long the BGW will shut down to prevent damage to both the BGW and the c...

Page 2: ...has be made between the CONFIG input and the Minus The LED will blink one time when the connection has been made for approx 2 seconds Once this is done the connection has to be disconnected The same c...

Page 3: ...de De plus la sortie d alarme STATUS indique la pr sence de surtension une fr quence de 1 Hz Cette information est galement communiqu e par la LED Protection contre la surcharge L lectricit qui passe...

Page 4: ...e de programmation il faut tablir un contact entre l entr e de CONFIG et la borne n gative La LED 1 se met clignoter d s qu un contact a t tabli pendant 2 secondes D s que cela se produit le contact d...

Page 5: ...US tambi n indicar con una frecuencia de 1Hz que se ha detectado una sobretensi n Esta informaci n tambi n se indicar por medio del LED Control de sobrecorriente Se mide constantemente la corriente qu...

Page 6: ...GURAR PROGRAMACI N Para iniciar el modo de configurar programaci n debe establecerse una conexi n entre la entrada de CONFIG y el min Una vez se haya establecido la conexi n durante 2 segundos el LED...

Page 7: ...ONS Minimum wire diameter 1 5 mm2 Faston plug 6 3 mm MECHANICAL Mounting hole 4 5 mm Distance between mounting holes centre to centre 1 mm 100 mm Weight 295 g Dimensions H W L 1 mm 39 76 111 mm IP Cod...

Page 8: ...anual 11004 BGW 40 60 1222 Battery Guard Models BGW 40 BGW 60 Please read this manual BEFORE operating the units Owner s Manual 11004 BGW 200 xx23 LOAD BATTERY REMOTE OFF CONFIG FUSE 5A STATUS ALARM F...

Reviews: