• The product may only be installed by qualified

 

electricians who are fully aware of the require-

ments for working with high battery voltages.

• The use of poor/ bad connection material and/or

 

wires that are too thin can damage the BGW.

• A short circuit between the battery’s positive and

 

negative terminals can cause serious damage to

 

the system.

• Always use fuses of the correct value.
• Use a 

1.5 mm

2

 with a 

5A fuse for the BGW

-

200 

from the battery (-)

 

to the BGW for the negative (–) 

connection. 

Use this connection only for the BGW!

WIRING DIAGRAM (please see last page)

OPERATION

Input voltage protection

The input voltage protection values (undervoltage 
threshold, undervoltage reset, overvoltage threshold 
and overvoltage reset) can be set by the user.  
Please see “CONFIGURE/Programming” how to  
set these values.

Undervoltage

If the BGW’s input voltage drops below the 
undervoltage threshold for 15 seconds, the status/
alarm output will turn on. The LED will also indicate 
undervoltage. The BGW will shut down one minute 
later and the alarm output and LED will turn off.
When the BGW’s input voltage exceeds the reset 
threshold for 5 seconds, the BGW will turn back 
on, and the LED will indicate that the BGW is active 
again.

Overvoltage

The BGW will shut down if the input voltage exceeds 
the overvoltage threshold for 0.5 seconds.  
The status/alarm output and LED will flash/switch 
with a frequency of 1 Hz.

Overcurrent protection

The current through the BGW is constantly monitored. 
If an excessive current flows through the BGW for 
too long, the BGW will shut down to prevent damage 
to both the BGW and the connected equipment.  
The BGW will turn on again after 1 minute.

Temperature protection

The BGW will shut down immediately if its 
temperature exceeds 85 °C. The LED will indicate 
a fault. The BGW will turn on again after 1 minute if 
the temperature has dropped below 75 °C.

Ground Loss protection

The BGW will shut down if it detects that the minus 
(–) is disconnected on the supply (battery) side.  

OWNERS MANUAL

DESCRIPTION

The Battery Guard Waterproof BGW

-

200 

(hereafter referred to as the BGW) is an intelligent, 
user-programmable, fully waterproof battery guard.  
The BGW has additional options for a remote off 
switch and an alarm output for connecting a buzzer, 
LED strip or relay. To ensure low losses, the BGW is 
provided with two threaded rod and nut connections; 
input+ and . The other connections (Minus-, 
Remote Off-, Config-input and Status/alarm output) 
are connected via 6.3 mm faston connectors.  
The BGW is equipped with a bright status LED 
displaying the different functional stages. The BGW 
features an “automatic board system detection”, 
this enables to automatically detect if the BGW is 
connected to a 12 V or a 24 V system.

INSTALLATION

Install the BGW on a cooling (metal) surface allowing 
to dissipate the heat generated. Use a maximum 
cable length of 50 cm between the battery and the 
BGW will ensure accurate monitoring the battery 
voltage.

Please note!

EN

Battery Guard Waterproof BGW

-

200

Summary of Contents for BGW-200

Page 1: ...Overcurrent protection The current through the BGW is constantly monitored If an excessive current flows through the BGW for too long the BGW will shut down to prevent damage to both the BGW and the c...

Page 2: ...has be made between the CONFIG input and the Minus The LED will blink one time when the connection has been made for approx 2 seconds Once this is done the connection has to be disconnected The same c...

Page 3: ...de De plus la sortie d alarme STATUS indique la pr sence de surtension une fr quence de 1 Hz Cette information est galement communiqu e par la LED Protection contre la surcharge L lectricit qui passe...

Page 4: ...e de programmation il faut tablir un contact entre l entr e de CONFIG et la borne n gative La LED 1 se met clignoter d s qu un contact a t tabli pendant 2 secondes D s que cela se produit le contact d...

Page 5: ...US tambi n indicar con una frecuencia de 1Hz que se ha detectado una sobretensi n Esta informaci n tambi n se indicar por medio del LED Control de sobrecorriente Se mide constantemente la corriente qu...

Page 6: ...GURAR PROGRAMACI N Para iniciar el modo de configurar programaci n debe establecerse una conexi n entre la entrada de CONFIG y el min Una vez se haya establecido la conexi n durante 2 segundos el LED...

Page 7: ...ONS Minimum wire diameter 1 5 mm2 Faston plug 6 3 mm MECHANICAL Mounting hole 4 5 mm Distance between mounting holes centre to centre 1 mm 100 mm Weight 295 g Dimensions H W L 1 mm 39 76 111 mm IP Cod...

Page 8: ...anual 11004 BGW 40 60 1222 Battery Guard Models BGW 40 BGW 60 Please read this manual BEFORE operating the units Owner s Manual 11004 BGW 200 xx23 LOAD BATTERY REMOTE OFF CONFIG FUSE 5A STATUS ALARM F...

Reviews: