Using the inverter Sine Wave lnverter
inches of the battery. Connect the positive cable to the red positive
terminal.
Warning!
In order for the integrated residual current-operated protective
device of the 60S-12A/E, 60S-24A/E, 100S-12A/E, 100S-24A/E,
150S-12A/E, 150S-24A/E, 200S-12A/E and 200S-24A/E inverters
to work properly, the earth connection of the inverter (fig. 4, page
2 / fig. 14, page 7) must be electrically connected to the chassis of
the vehicle or boat.
Lay the flexible earth cable from the earthing point of the vehicle to the
earthing point of the inverter.
Connect the earth cable to the chassis terminal (fig. 4, page 2 / fig. 14,
page 7).
Warning!
Reverse polarity connection of the battery wires can damage the
inverter.
8 Using the inverter
60S-12A/E, 60S-24A/E, 100S-12A/E, 100S-24A/E:
Always connect only one consumer unit to the 115V or 230 V socket (fig.
1.5, page 1)on the front of the device.
150S-12A/E, 150S-24A/E, 200S-12A/E, 200S-24A/E:
Always connect max two consumer unit to each of the 115V or 230 V
sockets (fig. 10.6, page 5) on the front of the device.
Switching on
Switching on the inverter via the ON/OFF-switch (fig. 1.1, page 1 / fig. 10.2,
page 5). When switching on, the ”Power” LED (fig. 1.2, page 1 / fig. 10.3,
page 5) illuminates.
Malfunctions
When the battery voltage falls below 10.7 V (60S-12A/E, 100S-12A/E, 150S-
12A/E, 200S-12A/E) resp. 21.4 V (60S-24A/E, 100S-24A/E,