![Samlex Europe WSC-1215 Manual Download Page 26](http://html1.mh-extra.com/html/samlex-europe/wsc-1215/wsc-1215_manual_3735524026.webp)
26
9
Using the Charger
ENG
"E.Q." LED
"STATUS" LED
Status
Red, constantly lit
I phase
Orange, constantly lit
Uo phase
Green, constantly lit
U phase
Red, constantly lit
Red, constantly lit
I phase, Equalization is acti-
vated
Red, constantly lit
Orange, constantly lit
Uo phase, Equalization is
activated
Red, constantly lit
Green, constantly lit
U phase, Equalization is
activated
Red, constantly lit
Equalization is executed
Red, flashing
I phase, half power
Orange, flashing
Uo phase, half power
Green, flashing
U phase, half power
Green, double flashing
Power supply mode
Red, slowly flashing
Stand-by mode (RC-600)
10
Trouble Shootings
10.1 The battery voltage would NOT increase after charging
• If possible, measure with a suitable multi-meter during the charging to verify if the voltage at the
battery terminals increases.
• Determine whether the terminals are connected properly to the battery poles. Clean the battery poles
if necessary to ensure better connection.
10.2 The battery is NOT fully charged after a charging time about 20 hours
• Disconnect the power to the charger.
• Remove the battery from the charging terminals and wait for a few minutes.
Then, measure the voltage at the battery terminals with the multi-meter.
Table 9-2 Normal Functional Check Table
Summary of Contents for WSC-1215
Page 3: ...3 Figure 4 WSC 1215 WSC 2408 Charger Top View mm Figure 3 Charger Rear View...
Page 5: ...5 Figure 8 Making Connections Figure 7 WSC 1230 WSC 2415 Charger Side View mm...
Page 6: ...6 Figure 9 Cable Setup Figure 10 Fork...
Page 7: ...7 Figure 12 Temperature Sensor TF 100 Figure 11 Switch...
Page 8: ...8 Figure 14 Remote Controller RC 600 Dimension mm Figure 13 Remote Controller RC 600...
Page 9: ...9 Figure 16 Remote Controller RC 601D Dimension mm Figure 15 Remote Controller RC 601D...
Page 10: ...10 Figure 18 Temperature Sensor Setup Figure 17 Making Connections RC 601D...