![Samlex Europe WSC-1215 Manual Download Page 23](http://html1.mh-extra.com/html/samlex-europe/wsc-1215/wsc-1215_manual_3735524023.webp)
23
RC-600 buttons
Charger working mode
Half power
Equalization
Others
Power Supply
"HALF POWER"
pressed
Exit "HALF
POWER"
("STATUS" LED
lights)
VOID
Enter "HALF
POWER"
("STATUS" LED
flashing)
VOID
S3 "E.Q." pushed
VOID
VOID
Equalization
("E.Q." LED
lights Red)
VOID
"ON/OFF" pressed
Stand by
("STATUS" LED
slowly flashing
Red)
Stand by
("STATUS" LED
slowly flashing
Red)
Stand by
("STATUS" LED
slowly flashing
Red)
Stand by
("STATUS" LED
slowly flashing
Red)
9
Using the Charger
ENG
Table 9-1 VOID Setting table for pressing button on remote controller
Note
• The power switch at the unit must be switched ON, so that the unit can be switched ON and OFF
with the remote control.
• The "ON/OFF" button on the RC-600 should be pressed for 2 seconds to switch OFF the battery
charger, and 0.5 second to turn ON.
9.3 Units with Temperature Sensor TF-100
A temperature sensor (Figure 12 Temperature Sensor TF-100, Page. 7) can be connected in
order to provide the optimum charging functioning. The charging voltages, as can be seen
from the following diagrams, vary, depending on the battery temperature.
Summary of Contents for WSC-1215
Page 3: ...3 Figure 4 WSC 1215 WSC 2408 Charger Top View mm Figure 3 Charger Rear View...
Page 5: ...5 Figure 8 Making Connections Figure 7 WSC 1230 WSC 2415 Charger Side View mm...
Page 6: ...6 Figure 9 Cable Setup Figure 10 Fork...
Page 7: ...7 Figure 12 Temperature Sensor TF 100 Figure 11 Switch...
Page 8: ...8 Figure 14 Remote Controller RC 600 Dimension mm Figure 13 Remote Controller RC 600...
Page 9: ...9 Figure 16 Remote Controller RC 601D Dimension mm Figure 15 Remote Controller RC 601D...
Page 10: ...10 Figure 18 Temperature Sensor Setup Figure 17 Making Connections RC 601D...