background image

5

1. INTRODUCTION

Thank you for purchasing a Samlex Europe (Samlex) Elogic DC to DC battery charger.  
Please read this owner’s manual for information about using the product correctly and safely. 
Keep this owner’s manual and all other included documentation close to the product for  
future reference. For the most recent manual revision, please check the downloads section  
on our website.
 
The purpose of this owner’s manual is to provide explanations and procedures for installing, 
configuring and operating the battery charger. The installation instructions are intended 
for installers that should have knowledge and experience in installing electrical equipment, 
knowledge of the applicable installation codes, and awareness of the hazards involved in 
performing electrical work and how to reduce those hazards.

1.1 

Intended product use

The Elogic DC to DC battery chargers are primarily intended to charge an auxiliary or service 
battery from a vehicle starter battery. The input battery voltage can be above, below or  
equal to the output battery voltage. An Elogic DC charger allows the auxiliary battery to be 
perfectly charged regardless of the input voltage, while being protected against damage due  
to peak voltages.

The Elogic DC battery chargers are compatible with vehicles that are equipped with variable 
output smart alternators (EUR 6+). The Elogic DC charger can start charging based on a 
programmable input voltage range only, or in combination with an engine run signal. There is 
also a separate (BMS-) control input available that enables external control for charger-on  
and -standby. 

1.2 

Important safety information 

This section contains important safety information for the Elogic DC battery charger. Each time, 
before using the Elogic DC battery charger, READ ALL instructions and cautionary markings on 
or provided with the battery charger, and all appropriate sections of this guide.  
This battery charger contains no user serviceable parts. Opening up the battery charger will 
void product warranty.
 

WARNING

FIRE AND/OR CHEMICAL BURN HAZARD
Do not cover or obstruct any air vent openings and/or install in a zero clearance compartment.

WARNING

SHOCK HAZARD. KEEP AWAY FROM CHILDREN!
Avoid moisture ingress. Never expose the unit to snow, water, etc.

 

Summary of Contents for ELOGIC

Page 1: ...INTELLIGENT DC DC BATTERYCHARGER ELOGIC Owners Manual Please read this manual before operating your Elogic Batterycharger Model No EL 12 12 50 12V 50A EL 12 24 30 24V 30A...

Page 2: ...2...

Page 3: ...ES COSTS OR EXPENSES WHETHER SPECIAL DIRECT INDIRECT CONSEQUENTIAL OR INCIDENTAL WHICH MIGHT ARISE OUT OF THE USE OF SUCH INFORMATION THE USE OF ANY SUCH INFORMATION WILL BE ENTIRELY AT THE USER S RIS...

Page 4: ...2 3 Wiring details 8 3 GENERAL FUNCTIONALITY 14 3 1 The charging process 14 3 2 Charger operation using the main On Off control input 14 3 3 Charger operation without using the main On Off control in...

Page 5: ...the output battery voltage An Elogic DC charger allows the auxiliary battery to be perfectly charged regardless of the input voltage while being protected against damage due to peak voltages The Elogi...

Page 6: ...losive gases DO NOT smoke or have an open spark or fire near the system 7 Never attempt to re charge a damaged frozen or non rechargeable battery 8 Keep unit away from moist or damp areas 9 Avoid drop...

Page 7: ...se an appropriate mounting location in a well ventilated room that is protected against rain snow spray vapour moisture and dust 2 Make sure that the ambient temperature is between 20 C and 60 C Above...

Page 8: ...user safety during installation please make sure that the output of the supplying source is switched off temporary remove fuses from the fuseholders and that no consumers are connected to the batteri...

Page 9: ...r grommets over these cables like shown in the next image When the DC cables are connected to the charger the rubber grommets can be slid towards the charger s front panel until the screw connections...

Page 10: ...ntly sized for the expected current Always keep the cable length as short as possible Model Minimum Cable size Recommended Cable size Battery fuse quick type EL 12 12 50 16mm AWG6 25mm AWG4 70 90Amp E...

Page 11: ...de In this mode the charger stops charging but the internal circuits stay active to immediately resume charging once allowed again This input can be used to connect to a Lithium battery BMS in order t...

Page 12: ...age 13 6V 27 2V On On LiFePo4 Bulk Abs voltage 14 4V 28 8V Float voltage 13 8V 27 6V DIP switch 3 is reserved for future use default off DIP switch 4 can be used to bypass the On Off control input see...

Page 13: ...that is being charged output battery The charger automatically compensates the charge voltages against battery temperature This means that the charge voltages are slightly increased at lower temperat...

Page 14: ...charge When the charge current has dropped below a certain value the Float stage will be entered For lithium batteries more than 80 of charge has been returned to the battery already So for this chem...

Page 15: ...allowed to be exceeded for a longer time than the fast off level This results in a stable charge process while still avoiding a too deeply discharged input battery CAUTION If the main On Off control i...

Page 16: ...Error see LED error table below Output LED Off Charger off or charging still blocked by input conditions not being met Flashing green Charging in progress Continuous green Charging finished Float sta...

Page 17: ...capacity Incorrect absorption charge voltage setting Check the battery type selection for correct setting Or adjust the absorption voltage Incorrect charge current setting Make sure that the maximum...

Page 18: ...4 If none of the above remedies will help solving the problem you encounter it s best to contact your local Samlex distributor for further help and or possible repair of your Elogic DC unit Do not di...

Page 19: ...ctions 3x M6 screw terminal Enclosure body size HxWxD 70 x 128 x 170mm Total weight 1 2kg Protection class IP21 Standards EMC 2014 30 EU Low voltage directive 2014 35 EU RoHS 2011 65 EU Automotive EN5...

Page 20: ...roduct and product malfunctioning Since Samlex cannot control the use and installation according to local regulations of their products the customer is always responsible for the actual use of these p...

Page 21: ...y charger MODELS EL 12 12 50 EL 12 24 30 Conforms to the requirements of the following Directives of the European Union EMC Directive 2014 30 EU Low voltage Directive 2014 35 EU Automotive Directive 2...

Page 22: ...www samlex com www samlex solar com...

Reviews: