Samlex Europe BSWM 160 DUAL Owner'S Manual Download Page 2

FEATURES

 

•  Intelligently driven 160 A relay 
•  Motor status detection through vibration 
•  Low power consumption
•  Simple installation 
•  Automatic 12 V/24 V system detection

PURPOSE

The BSWM160 (hereinafter: BSWM)is a high-
capacity mechanical switch with integrated vibration 
(i.e. motion) detection that can be used in situations 
where 2 batteries are present, for example, in 
trucks, caravans and campervans.

For many modern vehicles it is no longer possible 
to read whether a vehicle is switched ‘on’ by 
measuring the battery voltage. The BSWM has a 
sensor that detects vibrations. The BSWM can detect 
whether a vehicle is on based on the measured 
vibrations.

Since every vehicle is unique and has its own 
vibration frequency and amplitude, the user can set 
the sensitivity of the BSWM. The actions that must 
be performed to set the sensitivity of the BSWM are 
listed in the “Configure” section.

INSTALLATION 

Connections

STATUS  Start-Assist Input connection.
MINUS 

 Negative (–) connection. [

Note:

 it must 

always be connected through a 3 A fuse.] 

CONFIG   Input connection configuration.
A1 

Main/start battery positive (+) terminal. 

A2 

Auxiliary battery positive (+) terminal.

Connection method

Step 1.  The negative terminal (–) of the batteries 

must be connected to connection MINUS of 
the BSWM through a 3 A fuse. 

Step 2.  The positive terminal (+) of the main battery 

must be connected to A1 of the BSWM.

Step 3.  Connect the positive terminal (+) of the 

auxiliary battery to connection A2 of the 
BSWM.

Warnings:

•  The product must only be connected by skilled 

fitters/mechanics who are aware of the regulati-
ons for working with high battery voltages.

•  Using inferior connection material and/or wiring 

that is too thin may damage the product.

•  A short circuit between the positive and negative 

terminals of the battery may severely damage 
your system.

•  Always use fuses between the battery and the 

BSWM.

OPERATION

The BSWM can operate in three different ways. 
You can select a purely voltage-dependent control. 
Another option is to select a system that reacts to 
vibrations of the vehicle in which it can be found. 
You can also select a combination of both systems.

Vibration detection [positions 4 to 17]

Using the internal vibration sensor, the BSWM can 
detect whether a vehicle is switched ‘on’ or being 
driven. As can be seen in the table below, the BSWM 
operates purely on vibration detection in positions 
4 to 17.

Voltage-dependent control [position 3]

The BSWM will be set as a voltage-dependent 
control in position 3. The relay will be switched on 
when starting up. If the voltage is below 11.8 V for  
4 seconds, below 12.8 V for 60 seconds or below 
16.0 V for 0.5 seconds, the relay will switch off.  
If the relay is switched off, it will only switch on 
again if it is below 15.8 V for 5 seconds (when it 
detects overvoltage) or above 13.2 V for 7 seconds 
(when it detects undervoltage).

Combination [positions 1 & 2]

In positions 1 and 2, the BSWM will switch based on 
both vibration detection and detected changes in the 
input voltage.

OWNERS MANUAL

EN

Summary of Contents for BSWM 160 DUAL

Page 1: ...attery Charger Intelligent Battery Separator BATTERY SEPARATOR Smart Battery Charger Please read this manual before operating your separator Owners Manual Gebruiksaanwijzing Bedienungsanleitung Mode D...

Page 2: ...nal of the auxiliary battery to connection A2 of the BSWM Warnings The product must only be connected by skilled fitters mechanics who are aware of the regulati ons for working with high battery volta...

Page 3: ...witched on after detecting the last vibration Once the configuration connection of the BSWM CONFIG connection is connected to the positive terminal of the primary battery for 4 seconds the LED will bl...

Page 4: ...gevoeligheid van de BSWM instellen De handelingen die uitgevoerd moeten worden om de gevoeligheid van de BSWM in te stellen staan in het hoofdstuk Configureren vermeld INSTALLATIE Aansluitingen STATUS...

Page 5: ...derstaande tabel te zien is werkt de BSWM puur op trillingsdetectie in stand 4 t m 17 Spannings afhankelijke regeling stand 3 In stand 3 zal de BSWM ingesteld zijn als een spannings afhankelijke regel...

Page 6: ...e primaire batterij zal de LED de ingestelde stand nogmaals weergeven voorbeeld Configuratie 4 is door een gebruiker ingesteld de LED zal 4 maal knipperen CONFIGURATIETABEL Gevoeligheid Tijd sec 1 Com...

Page 7: ...igen Installateuren Monteuren angeschlossen werden die die Vorschriften f r das Arbeiten mit hohen Batteriespannungen kennen Bei Gebrauch von untauglichem Anschlussmaterial und oder zu d nnen Dr hten...

Page 8: ...Sobald der Konfigurationsanschluss des BSWM Anschluss CONFIG 4 Sekunden mit dem Pluspol der prim ren Batterie verbunden ist wird die LED Anzeige 1 Mal kurz aufleuchten Sobald dies geschehen ist muss d...

Page 9: ...rer la sensibilit du BSWM Les manipulations effectuer pour configurer la sensibilit du BSWM sont d taill es dans la section Configuration MONTAGE Bornes STATUS Raccordement Entr e Start Assist MINUS B...

Page 10: ...en positions 4 17 comprise le BSWM fonctionne purement sur la base de la d tection des vibrations R glage d pendant de la tension position 3 En position 3 le BSWM fonctionne en r glage d pendant de la...

Page 11: ...itive de la batterie primaire le voyant LED affiche une nouvelle fois la configuration s lectionn e exemple si un utilisateur choisit la configuration 4 le voyant LED clignotera 4 fois TABLEAU DE CONF...

Page 12: ...2 del BSWM Advertencias Este producto s lo puede ser conectado por instaladores mec nicos expertos que conozcan debidamente la normativa para trabajos con tensiones de bater a altas El uso de material...

Page 13: ...as detectar la ltima vibraci n Cuando la conexi n de configurar del BSWM conexi n CONFIG se conecte durante 4 segundos con el polo positivo de la bater a principal el LED parpadear 1 vez brevemente En...

Page 14: ...a conmutable 160 A Conexiones Pemos M8 Faston 6 3 mm Di metro de cable m nimo 50 mm Peso 470 g Tama o L x An x Al 108 mm x 72 mm x 58 mm Absorci n de corriente Rel cerrado 340 mA 13 5 V 170 mA 27 0 V...

Page 15: ...the following products PRODUCT TYPE Microprocessor controlled Battery Separator BRAND Samlex Standards to which conformity is declared EN 61000 6 2 2005 EN 61000 6 3 2007 and Automotive Directive 2004...

Page 16: ...BSWM 160 DUAL 080520 www samlex com www samlex solar com...

Reviews: