![Sames Inocoat Inogun M Instruction Manual Download Page 12](http://html1.mh-extra.com/html/sames/inocoat-inogun-m/inocoat-inogun-m_instruction-manual_3697874012.webp)
12
Member of Exel group
DRT7132
D - 2022 /09
14The electrostatic powder spraying equipment should only be operated if it is in perfect condition. Damaged
equipment must be removed from service immediately and repaired.
15Before cleaning the projectors or doing any other work in the spray area, the power supply to the high-voltage
generator must be disconnected, protected against restarting and the HV circuit protected. (projector)
discharged to ground.
Cleaning must be carried out in mechanically ventilated areas.
16Inside the booth it is forbidden to use naked flames, glowing objects or devices likely to produce sparks.
It is also forbidden to store flammable products, or recipients that have contained them, in the vicinity of the
booth.
The surrounding area must be kept clear and clean.
17In the explosive zone, it is forbidden to use non-certified electrical or non-electrical equipment such as
electrical extension cords, multi-sockets, switches, etc.
A warning sign in a language understood by the operator, summarizing the safety rules described above, must be
prominently displayed in the vicinity of the powder spray station.
1.6. Regulatory tests to be carried out on the equipment according to standard EN 50050-2
The tests must be carried out on the spraying equipment. The tests must be carried out by competent personnel
and include the tests described below (see § 6.2.3 table 1 in standard EN 50050-2).
(*) Intervals depend on operating and local conditions.
1.7. Important recommendations
1.7.1. Ventilation
Do not start the powder application with the
Inogun M
spray gun until the spray booth ventilation system is
switched on. If the ventilation is switched off, toxic substances or dust may remain in the spray booth and cause a
risk of fire, poisoning or irritation.
1.7.2. O-ring seals
Use the seals recommended in this manual.
1.7.3. Ambient temperature
The spray gun is designed to normally operate at an ambient temperature comprised between 0°C and + 40°C.
The storage temperature must never 60°C.
Type of test
Requirements
Grounding measures
Weekly
Forced ventilation interlock and manual electrostatic spraying
equipment
Annual
Checking manual electrostatic spraying equipment for damage
Weekly
Summary of Contents for Inocoat Inogun M
Page 1: ...Instruction manual DRT7132 D 2022 09 Inogun M Inogun M Powder Spray Gun...
Page 61: ...61 DRT7132 D 2022 09 Member of Exel group 10 Appendices 10 1 Preventive maintenance plan...
Page 64: ...62 Member of Exel group DRT7132 D 2022 09 10 2 EU and UK declarations of conformity...
Page 69: ...Sames 13 Chemin de Malacher 38240 Meylan France 33 0 4 76 41 60 60 www sames com...