12.2. Data exchange
12.2.1.
From CAN to the
Inobox
module
8 bytes are exchanged from a CAN module to the
Inobox.
Byte
Label
Description
Unit
Max.
0
CAN Command
Commands requested by the CAN (see the detailed
description hereafter)
-
1
CAN Current Setpoint
Current setpoint requested by the CAN.
This setpoint is applied only if the CAN_Control mode is
active and the HV trigger is activated
μ
A
110
2
CAN Voltage Setpoint
High voltage setpoint requested by the CAN.
This setpoint is applied only if the CAN_Control mode is
active and the HV trigger is activated.
kV
100
3
CAN Injection Setpoint
Injection setpoint requested by the CAN.
This setpoint is applied only if the CAN_Control mode is
active and the HV trigger is activated.
Point
100
4
CAN Dilution Setpoint
Dilution setpoint requested by the CAN.
This setpoint is applied only if the CAN_Control mode is
active and the HV trigger is activated.
Point
100
5
CAN Blowing Setpoint
Blowing setpoint requested by the CAN.
This setpoint is applied only if the CAN_Control mode is
active and the HV trigger is activated.
Point
30
6
CAN Fluidisation Setpoint
Fuidisation setpoint requested by the CAN.
This setpoint is applied only if the CAN_Control mode is
active and the HV trigger is activated.
Point
50
7
Spare
Byte
CAN Command
7
ON/OFF trigger
(For automatic projector)
HV trigger start (set to 1)/ stop (set to 0) request.
The request is only taken into account if the CAN control is enabled by the
Inobox
and if the HV pilot is requested.
This boolean is also used to acknowledge a fault, if the trigger is activated, it
must first be switched off and then an ON/OFF trigger must be performed to
request an acknowledgment (falling edge detected).
6
Cleaning ON/OFF
Cleaning start (set to 1) / stop (set to 0) request.
The request is only taken into account if the CAN control is enabled by the
Inobox
and if the cleaning pilot is requested
5
4
3
Cleaning control request
The CAN asks to control the cleaning (active if set to 1), to 0 wired control.
The request is only taken into account if the CAN control is enabled by the
Inobox
2
HV control request
(For automatic projector)
If an automatic projector is connected, request for high voltage control via
the CAN (if set to 1).
The request is only taken into account if the CAN control is enabled by the
Inobox
.
1
0
CAN control request
The CAN asks to control the
Inobox
(active if set to 1)