Index revision : F - November 2017
30
7012
7.
Cleaning procedures
Before any operation, refer to the health and safety rules (
see § 1.4 page 6
).
According to the frequency of use and in all the cases at the end of each cycle
• Stop the atomizer and switch off the power supply.
WARNING : Always wear safety goggles.
Whenever solvent is handled, rubber gloves must be worn.
Work in a well ventilated area whenever solvent is used.
WARNING : It is imperative to pass a rag soaked with water on the atomizer before cleaning it
using a rag and an approved cleaning product. Do not use a manual solvent gun.
WARNING : Do not soak the turbine in solvent.
Under no circumstances must the atomizer or any of its components be sprayed with solvent or
water at high or low pressure.
WARNING :
SAMES KREMLIN
disadvises the use of anti-static plastic films to protect bodies
and insulating covers of the atomizers. These films are conductive and can short-circuit the high
voltage.
SAMES KREMLIN
forbids the use of adhesives on the insulating parts of the atomizers. The
glue of the adhesives is conductive and thus can short-circuit the high voltage.
SAMES KREMLIN
also forbids the use of absorbent textile cover to protect bodies and insu-
lating covers of atomizers. Textile covers retain the cleaning products and paint what can gen-
erate problems of high voltage (drilling, ionization, degradation of the material...).
Thus,
SAMES KREMLIN
recommends the use of insulating grease for protection of the atom-
izers.
In any case, insulating protection means must be used to prevent the slightest risk of current
overconsumption.
This is why, insulating protection means must be renewed on a regular basis.
Procedure
Components
Frequency
A
Outer cover, bellcup exterior.
8 hours
B
Bellcup, shaping air assembly, injector
120 hours