582156110-EN-indC-Pump-20F50 pH.docx
20/11/2020
99
Unscrew the suction valve (50) with a 41 mm wrench.
Remove the gasket (42) with a flat screwdriver.
Remove the locking ring (40) with a flat screwdriver.
Remove the ball (39).
Clean the parts, change the gasket (42) and
reassemble the ball (39) and the retaining ring (40).
Tools needed
50
41
Summary of Contents for 20F50
Page 27: ...582156110 EN indC Pump 20F50 pH docx 20 11 2020 27 Air supply assembly...
Page 28: ...20 11 2020 582156110 EN indC Pump 20F50 pH docx 28 Fluid filter 3 8 model 250 bar 3625 75 psi...
Page 32: ...20 11 2020 582156110 EN indC Pump 20F50 pH docx 32...
Page 58: ...20 11 2020 582156110 EN indC Pump 20F50 pH docx 58 Remove the fluid tube 47 and the nut...
Page 76: ...20 11 2020 582156110 EN indC Pump 20F50 pH docx 76 Remove the fluid tube 47 and the nut...
Page 97: ...582156110 EN indC Pump 20F50 pH docx 20 11 2020 97 Remove the fluid tube 47 and the nut...
Page 105: ...582156110 EN indC Pump 20F50 pH docx 20 11 2020 105 Remove the fluid tube 47 and the nut...
Page 115: ...582156110 EN indC Pump 20F50 pH docx 20 11 2020 115 Remove the fluid tube 47 and the nut...
Page 168: ...20 11 2020 582156110 EN indC Pump 20F50 pH docx 168 Package of seals 144 951 090...