20/11/2020
582156110-EN-indC-Pump-20F50 pH.docx
50
12
Maintenance
12.1
Preventive Maintenance Plan
Attention
Before any intervention, it is imperative to follow the
decompression procedure and the safety instructions.
During a long duration shutdown, stop the pump when
the piston is in the down position.
Pump
Make sure that the pump is clean and in good condition to increase
equipment working life.
Make sure that the suction strainer is clean and in good condition.
Regularly clean it and change it if necessary.
Flush the pump as often as necessary, specially when spraying
pigment-filled material.
Attention
Whatever the case, when stopping the pump, always
leave it filled with fluid.
For a short duration shutdown, if the flushing has not been
carried out, leave the pump filled with fluid.
For a long duration shutdown, after flushing the fluid,
leave the pump filled with solvent.
Summary of Contents for 20F50
Page 27: ...582156110 EN indC Pump 20F50 pH docx 20 11 2020 27 Air supply assembly...
Page 28: ...20 11 2020 582156110 EN indC Pump 20F50 pH docx 28 Fluid filter 3 8 model 250 bar 3625 75 psi...
Page 32: ...20 11 2020 582156110 EN indC Pump 20F50 pH docx 32...
Page 58: ...20 11 2020 582156110 EN indC Pump 20F50 pH docx 58 Remove the fluid tube 47 and the nut...
Page 76: ...20 11 2020 582156110 EN indC Pump 20F50 pH docx 76 Remove the fluid tube 47 and the nut...
Page 97: ...582156110 EN indC Pump 20F50 pH docx 20 11 2020 97 Remove the fluid tube 47 and the nut...
Page 105: ...582156110 EN indC Pump 20F50 pH docx 20 11 2020 105 Remove the fluid tube 47 and the nut...
Page 115: ...582156110 EN indC Pump 20F50 pH docx 20 11 2020 115 Remove the fluid tube 47 and the nut...
Page 168: ...20 11 2020 582156110 EN indC Pump 20F50 pH docx 168 Package of seals 144 951 090...
Page 173: ...582156110 EN indC Pump 20F50 pH docx 20 11 2020 173...