SAMES KREMLIN
- 5 -
N° : 578.087.120-UK-1907
5. START UP
Protective clothing (gloves, protective masks, glasses, hearing
protective earplug, protective clothing,…) should be worn to
comply with the recommendations.
The working area must be correctly ventilated.
BEFORE STARTING THE EQUIPMENT
Guards (air motor cover, coupling shields, housings …) have been designed for safe use
of the equipment.
The manufacturer will not be held responsible for bodily injury or failure and / or damage
to property due to removal or partial removal of the guards
GROUNDING OF THE PUMP
Unscrew the lock-nut (A), remove the washer (B), insert the lug (C) with its ground wire
(D) (minimum section : 1,5 mm
2
) between the washer (B) and the washer (D). Tighten
the lock-nut. Connect the other end of the wire to a real "ground", according to the
national rules.
A qualified electrician must check the ground continuity. If the continuity is not correct,
check the terminal, the electric wire, the U bolt and the ground point. Never operate
pump without revolving the trouble.
CONNECTION OF THE COMPRESSED AIR SUPPLY
For a correct operating and a long duration life of the motor, supply air must be filtered
and not lubricated.
- You must install a
pressure relief valve
after the air regulator and near to the inlet
motor to follow the pressure relief instructions.
- The motor air supply hose should have an internal diameter of at least 19 mm /
0.75".
- The motors are tested prior to their sending. Nonetheless, before coupling the
motor to the pump, you must operate the no load motor during a few minutes to a
maximum pressure of 2 bar / 29 psi.
Then, comply with the instructions as follows :
- Couple the motor to the required fluid section,
- Connect the main air supply to the motor,
- Adjust the pressure by means of the air regulator.