SAMES KREMLIN
- 9 -
N° 578.209.110-UK-1907
UPPER TIGHTNESS SEAL (25)
Disassembly
Unscrew the 8 screws (27).
Separate the fluid section (A) from the suction part
(B).
Remove the GT seal (25) by pulling the exhaust
flange (26) downwards.
Remove the O-ring seals (16 and 28).
Assembly
Place a new GT seal (25) into the discharge
flange (26) after having lubricated it.
Comply with the GT seal (25) installation order.
DETAIL VIEW
BELLOWS
This operation must be done after the separation of the lower part from the upper part of the fluid
section and after the dismounting of the upper thightness seal.
In the work table, prepare assembly, which consists of fluid section piston-exhaust flange while
following the procedure of the upper thightness seal (25).
Disassembly
- Remove the cylinder (17) from the suction bearing (11).
- Separate the suction bearing (11) from the motor by remowing the screws (15).
- Slide, then put aside the bellows-skirt-flange assembly.
- Remove the bellows flange (7) to take off the upper part of the bellows.
- Dismount the skirt (10).
Assembly
On the work table, prepare a bellows-skirt-flange set. You must :
- Install a new bellows (9) into the bellows flange (7).
- When installing the bellows, push it into skirt (10).
- Install the upper bellows flange (7).
- Slide the bellows-skirt-flange assembly along the motor rod.
Orientate and tighten it on air motor base by means of the 3 screws (15).
Nota : To make easier the reassembly, you can remove one of the three tie rods (19).
Couple product section (B) with the suction part (A).
25