Doc.-ID: 180528-PT08BA-SS-ExCam XPT-Q6055_en_rev.00.docx, Page 21 of 28
5.3.5
Fusing
PoE+ power supply requires no fuses.
The power supply fusing depends on the cable cross-section and length.
Attention!
Recommendation for fusing relates to 60W@24VDC at 100meters 1.5
mm
2
Attention!
When the heating switches on, there are high current peaks! Use slow-
blow fuses.
Attention!
Please pay attention to the national and international regulations re-
garding selectivity and line protection.
Potential/
Wire no.
Colour
(IEC60757)
Conductor
Voltage
Maximum power consumption/fus-
ing:
L+ / 1
BK
1.5mm
2
,
stranded wire
+24 VDC
60 W of continuous power
Fine-wire fuse
(L+) 6000 mA -T- slow-blow
(high inrush load!)
L- / 2
BU
1.5Mm2,
2
,
stranded wire
0 VDC / GND
PE
YE/GN
1.5Mm2,
2
,
stranded wire
PE
Tab. 5-12 Recommendation for fusing
5.3.6
Plug assignment (RJ45)
The data transfer of the ExCam XPT Q6055 series uses a 100 Mbit/s Ethernet connec-
tion (100BASE-TX).
If the cable termination uses a plug, (figure 5.3) it has to be plugged into the associated
slot of the network device. Prior to connecting it to the camera, the network device (PSE)
can already be supplied with power, hence there is no „power ON“ priority which has to
be observed.
Attention!
Use the appropriate RJ45 plug! Check shielding, cross-section and the
outside diameter of the cable!
Attention!
It is imperative to ensure a correct assignment of the individual wires
according to the EIA/TIA-568B"