LUBRICATION
The bearing housing has been emptied of oil prior to shipment and must
be refilled before starting. During operation, the oil level may slightly fall.
Refilling during operation should always be done through the cap hole of
the constant level oiler in the plastic cap there must always be oil.
When the pump is put into operation after prolonged shut-down, flush
bearings and bearing housing with petrol or benzol in order to remove
impurities, during the flushing procedure rotate the shaft slowly.
Oil Change:
It is recommended that for a new pump the oil should be
changed after 100 hours of operation for the first time and thereafter at
intervals of 6-12 months. Add oil when necessary.
TO INSTALL A CONSTANT LEVEL OILER AS BELOW:
1.Unscrew upper screw sub assembly from
lower sub assembly. (Refer Fig.1)
2.Fix lower sub assembly (elbow type) on
pump.
Please note Pump has two tapings.One tapping is for CLO and other is a drain,
which is at a lower height
FIRM
Lubricating oil for temperature up to 80°C
Speed up to 1500 rpm
Speed over 1500 rpm
Indian Oil
Servo system 150
Servo system 68
Hindustan
Petroleum
ESSTIC 55,
TERRESSO 56
ESSTIC 50
TERRESSO 52
Mobil
MOBIL VACTRA
Oil Heavy
MOBIL D.T.E
Oil Heavy
Vac HLP 49
MOBIL VICTRA
Oil Heavy Medium
MOBIL D.T.E
Oil Heavy Medium
Vac HLP 36
Shell
Shell Vitrea Oil 33,
Shell Oil 33
Shell Vitrea Oil 31,
Shell Tellus Oil 29