3.Once lower sub assembly is fixed, tighten locknut to ensure
that CLO is 90° with respect to ground.
4.Fill oil in pump with a can. Oil should be filled either by opening
breather of pump or from the lower sub assembly. (Ref. Fig.4)
5.Once initial oil level is maintained in pump, take upper sub assembly,
reverse, it and put it oil in dome through the hole by using a suitable funnel (3/4
th
full).
DO NOT UNSCREW DOME from the sub assembly to fill oil. (Ref.Fig.5)
6.Once oil is filled dome, reverse and screw it on the lower sub assembly.
Do not over tighten. Some bubbling will take place, this is O.K., bubbling
will stop once oil has reached its level. I=i.e. (Ref.Fig.6)
7.Once
bubbling has stopped ,the pump should be started .CLO will automatically
maintained oil level in pump. Refill oil whenever oil level in doom goes below level Y
ref.step 1,5,6.
Note:
1-In case of pump is already full of oil before installing CLO, it is
recommended to check oil level in sump as per step 4.
In case there is
excess oil, drain it out and bring it to half the elbow
overfilling oil will cause oil
to overflow from above the holder resulting in oil leakage.
Note:
2-Keep vent holes of breather in pump clean, if it is chocked it will cause leakage from oilcup.
Summary of Contents for ZM 375/00