ST320RF INSTRUCTION MANUAL
26
When operating in Failsafe mode, the LEDs will indicate the Receiver relay status as follows:
Mode
LEDs
Indication
On
Blue and Yellow
Each LED lights alternately,
approx. once per second
Off
Yellow
On
Cycle
Blue
On for 4 minutes,
off for 11 minutes
If required the user can switch to another mode ‘on the fly’ without having to reset the ST320RF; for
instance you can switch from Auto Mode to Manual Mode with the output relay being controlled
accordingly.
To illustrate this point, even when switched into Manual Mode the Receiver can still receive the RF signal
from the Control Centre and once the user switches to Auto Mode, the output relay will be controlled to
turn on or turn off automatically once more.
ST320RF Manual Version 005:Layout 1 21/10/10 15:32 Page 26