ENGLISH
5. PROGRAMMING
23
7.1
5.2 Advanced programming
START DELAY
OFF
RANGE 1min ÷ 99h 59min
STOP PRESSURE
3.0 bar
STOP PRESSURE
3.0 bar
IT IS USED TO SET THE
NECESSARY PRESSURE
ABOVE WHICH
THE MOTOR STOPS
MINIMUM PRESSURE
OFF
IT IS USED TO SET THE REQUIRED
PRESSURE BELOW WHICH THE
MOTOR STOPS. AT THE MOTOR
STARTING THIS PARAMETER IS
BYPASSED FOR 1 MINUTE
OFF
EXCLUDES
MINIMUM PRESSURE
10bar: 0.2 ÷ 8bar
16bar: 0.2 ÷ 14bar
TRANSDUCER:
25bar: 0.2 ÷ 23bar
10bar: 0.1 ÷ 7.8bar
16bar: 0.1 ÷ 13.8bar
TRANSDUCER:
25bar: 0.1 ÷ 22.8bar
OFF
IT EXCLUDES THE
MINIMUM PRESSURE
RESET
MINIMUM PRESSURE
RESET 0 h 5 m
IT IS USED TO SET THE
MINIMUM PRESSURE
RESET TIME
RANGE 1min ÷ 99h 59min
MINIMUM PRESSURE
DELAY 0m 30 s
IT IS USED TO SET
THE MINIMUM
PRESSURE
INTERVENTION DELAY
RANGE 1s ÷ 59min 59s
IT IS USED TO SET THE DELAY
FOR STARTING THE MOTOR WHEN
THE SYSTEM PRESSURE
DROPS BELOW THE
START PRESSURE
OFF
EXCLUDES
THE START DELAY
START DELAY
OFF
START DELAY
0h 2 min
TRANSDUCER
10 bar
TRANSDUCER
10 bar
TRANSDUCER
16 bar
IT IS USED TO SET THE FULL
SCALE OF THE TRANSDUCER
USED
START PRESSURE
2.5 bar
START PRESSURE
2.5 bar
IT IS USED TO SET THE
PRESSURE REQUIRED TO
START THE MOTOR
TRANSDUCER
25 bar
TRANSDUCER 10bar: 0.1 ÷ 7.9bar
TRANSDUCER 16bar: 0.1 ÷ 13.9bar
TRANSDUCER 25bar: 0.1 ÷ 22.9bar
MINIMUM PRESSURE
0.5 bar
MINIMUM PRESSURE
OFF
OFF
IT EXCLUDES THE
MINIMUM PRESSURE
DELAY
MINIMUM PRESSURE
RESET OFF
MINIMUM PRESSURE
RESET OFF
MINIMUM PRESSURE
DELAY OFF
MINIMUM PRESSURE