ITALIANO
TENSIONE MINIMA
207 V
TENSIONE MINIMA
207 V
SERVE AD IMPOSTARE LA
TENSIONE DI FUNZIONAMENTO
MINIMA DEL MOTORE
RANGE 180 ÷ 220V (SA640.xx)
RANGE 340 ÷ 380V (SA650.xx)
TENSIONE MASSIMA
253 V
TENSIONE MASSIMA
253 V
SERVE AD IMPOSTARE LA
TENSIONE DI FUNZIONAMENTO
MASSIMA DEL MOTORE
RANGE 230 ÷ 253V (SA640.xx)
RANGE 400 ÷ 440V (SA650.xx)
TENSIONE MINIMA
OFF
TENSIONE MASSIMA
OFF
OFF
ESCLUDE IL CONTROLLO
SULLA TENSIONE MINIMA
OFF
ESCLUDE IL CONTROLLO
SULLA TENSIONE MASSIMA
5. PROGRAMMAZIONE
11
PREMUTO SI RITORNA ALLA PRIMA
SCHERMATA DEL SETUP;
VEDI CAPITOLO 5.1
PREMUTO PER PIÚ DI 1s SI ESCE
DAL SETUP E SI SALVANO I
PARAMETRI IN MEMORIA
PULSANTE MANUALE
INSTABILE
PULSANTE MANUALE
INSTABILE
INSTABILE
AVVIA IL MOTORE
SOLO DURANTE LA PRESSIONE
SUL PULSANTE
MAN
PULSANTE MANUALE
STABILE
STABILE
AVVIA IL MOTORE CON UN
IMPULSO SUL PULSANTE
MAN;
ARRESTA IL MOTORE CON UN
IMPULSO SUL PULSANTE
RESET
ATTESA PRESENZA
RETE OFF
OFF
ESCLUDE L’ATTESA
PRESENZA RETE
ATTESA PRESENZA
RETE OFF
ATTESA PRESENZA
RETE 1 min
SERVE AD IMPOSTARE
L’ATTESA PRESENZA RETE
RANGE 1 ÷ 30min