background image

 

9. 

ASSEMBLY PROCEDURES 

 

STEP 1 
 

 

Put the 3 pcs post brackets on each position on the base as shown in the 
picture. 

 

Use 3 pcs M8 x 16 mm bolts to join the post brackets and stand. 

 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
STEP 2 
 

 

Put the post on the top of 3 pcs post brackets. 

 

Use 6 pcs M6 x 35 mm bolts and nuts to connect the post to the 3 pcs post 
brackets. Tighten the bolts and nuts. 

 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 

 

Square 
Metal 
Support 

Stand 

Bolt 

 

Post 

Nut 

Bolt 

Summary of Contents for SOD 12

Page 1: ...INSTRUCTIONS AND WARRANTY MODEL NO SOD 12 ...

Page 2: ...2 SALTON GAS PATIO HEATER ...

Page 3: ... in operation Do not move the heater after it has been turned off until the temperature has cooled down Keep the ventilation opening of the cylinder enclosure free and clear of debris Do not paint the radiant screen control panel or top canopy reflector Control compartment burner and circulation air passageways of the heater must be kept clean Frequent cleaning may be required as necessary The LPG...

Page 4: ...under Cleaning and Care section If upon relighting the problem reoccurs have your unit checked by an authorized service dealer 2 HEATER STAND AND LOCATION The heater is primarily for outdoor use only Always ensure that adequate fresh air ventilation is provided Always maintain proper clearance to combustible materials i e top 450mm and sides 600mm minimum Heater must be placed on level firm ground...

Page 5: ...mishandling in shipment or excessive pressure being applied to the heater Make a soap solution of one part liquid detergent and one part water The soap solution can be applied with a spray bottle brush or rag Soap bubbles will appear in case of a leak The heater must be checked with a full cylinder Make sure the safety control valve is in the OFF position Turn the gas supply ON In case of a leak t...

Page 6: ...out please repeat from Step 3 4 After the Pilot Flame is lit turn the Variable Control Knob to the minimum position and leave there for 5 minutes before turning the knob to the desired temperature position 5 2 TO TURN OFF THE HEATER 1 Turn the Variable Control Knob to the Pilot position 2 Press and turn the Variable Control Knob to the OFF position 3 Turn the valve on the gas supply cylinder compl...

Page 7: ...soft moist rag Do not clean heater with cleaners that are combustible or corrosive Remove debris from the burner to keep it clean and safe for use Cover the burner unit with the supplied protective cover when the heater is not in use 7 PARTS AND SPECIFICATIONS ...

Page 8: ... CSA certificates C Table of openings OPERATING PRESSURE MAIN JET PILOT JET 2 8 kP 1 9 mm 0 20 mm 8 ASSEMBLY PARTS Tools needed Open end wrench 10 13 mm Adjustable opening wrench 2 20 cm long Slip joint pliers 23 cm long Philips screwdriver w medium blade Spray bottle of soap solution for leakage test Parts supplied Stand with LPG tank housing Assembly post with 3 pcs post brackets 10 mm x 86 cm L...

Page 9: ...shown in the picture Use 3 pcs M8 x 16 mm bolts to join the post brackets and stand STEP 2 Put the post on the top of 3 pcs post brackets Use 6 pcs M6 x 35 mm bolts and nuts to connect the post to the 3 pcs post brackets Tighten the bolts and nuts Square Metal Support Stand Bolt Post Nut Bolt ...

Page 10: ... housing on the stand STEP 4 Fit the gas hose pipe nut to the burner gas inlet connector Tighten the gas hose pipe nut and gas inlet thread Fix the completed burner unit to the post by 4 pcs M6 x 10 mm bolts Tank Housing Bolt ...

Page 11: ...and burner are assembled according to instructions and all bolts and nuts are tightened Put washer Ø8 mm on each reflector support bolt STEP 6 Fasten the reflector with 3 pcs washers and 3 pcs M8 mm dome nuts Reflector Flat Washer Nut Reflector Nut Reflector ...

Page 12: ...nk housing and rest it on the post plate Connect the regulator to the gas tank and tighten it with adjustable wrench Connect the end thread of inlet gas hose to the regulator Put LPG gas tank on the stand Gas Cylinder Regulator ...

Page 13: ... of the hose and the regulator there are no user fitted parts available for this heater Should the heater not be functioning properly an authorized service agent must check it and if replacement parts are required they will ensure that the correct parts are supplied and fitted correctly It is recommended to have your heater checked at your local hardware store at the beginning of every season WARN...

Page 14: ... lit Debris around the Pilot Light Clean the dirty area Loose connections Tighten the connections Thermocouple is poor Replace the thermocouple Gas leak in the line Check connections Lack of fuel pressure Cylinder nearly empty refill with LPG Burner will not light Pressure is low Cylinder near empty refill with LPG Opening blocked Remove and clean Control not ON Turn valve ON Thermocouple poor Rep...

Page 15: ...or exchange the product in terms of this warranty subject to legislative requirements This warranty shall be valid only where the customer has not broken the product himself or used the product for something that it is not supposed to be used for The warranty does not include and will not be construed to cover products damaged as a result of disaster misuse tamper abuse or any unauthorised modific...