Installation
Electrical installation
Pluggable equipment
Pluggable equipment must be installed near an easily accessible socket outlet.
Permanently wired equipment - Isolator requirements
Permanently connected equipment must have a readily accessible disconnect
device incorporated in the fixed wiring such as an isolator or circuit breaker with at
least 3mm contact separation.
The isolator
MUST NOT
be installed into the flexible power cable supplied with the
unit.
DANGER: RISK OF ELECTRICAL SHOCK. NO USER SERVICEABLE
PARTS. REFER TO QUALIFIED SERVICE PERSONNEL FOR
SERVICE.
CAUTION: The power cable must be connected to an earth-grounded
electrical outlet. The electrical supply must have a circuit breaker with an
appropriate rating to protect from over-current conditions.
For your protection, all electrical (110V or 230V) equipment used out of
doors or in wet or damp conditions should be supplied from a correctly
fused power source and protected by an approved ground fault protection
device (RCD, GFCI etc.)
IF IN DOUBT SEEK ADVICE FROM A QUALIFIED ELECTRICIAN.