12
6.
When unLoAd is displayed in the PIECE WEIGHT window, it means the scale
will confirm the zero point once more. Remove the weight from the scale and
after the scale is stable and unit announciator is not flashing. Press the
ENTER key.
The scale goes through the start up routine and ends in normal
weighing mode.
If there is any error in the calibration, the scale will show
CAL. Err
.
The scale will try to return to the previous step.
7.
If you have problems, press the
On/Off
key to exit the calibration mode
and try the procedure again.
8.
Move the calibration switch back to normal weighing mode.
6.0
View Voltage and A/D Counts
You can view the battery voltage and A to D counts for diagnostic purposes.
Follow these steps:
1.
With the calibration switch in the normal weighing mode and the scale in
normal mode, press and hold the
On/Off
and
Tare
keys at the same time
until the scale beeps…
Vol. X.X
is displayed in the WEIGHT window, the word
codE
is
displayed in the PIECE WEIGHT window and the A to D counts
(code) is displayed in the COUNT window.
Vol.
stands for voltage and
X.X
is the current voltage of the battery. If
no battery is installed or the connection is not complete,
Vol. 7.2
will
be displayed.
When the current working voltage is lower than 5.7V, the
Low Batt
annunciator will light.
When the voltage is lower than 5.5V, the
Low Batt
annunciator will
light and the beeper will sound for approximately two minutes before
the scale turns itself off.
The A to D counts for an empty scale should be between 5000 and
100,000. This should be a positive number. The A to D counts for a
scale at full capacity should be above 300,000. If the A to D counts
are outside of these ranges or calibration and normal weighing
cannot be done, your scale’s loadcell has been permanently
damaged.
2.
To exit this mode, press the
On/Off
key…
The scale returns to normal mode.
When the scale displays "InP.Ld" (input load weight) in PIECE WEIGHT
window, 0 in WEIGHT window, input the number of total weight loaded on
scale by numerical keys. Press ENTER to confirm the input weight. The
input weight data will be displayed in WEIGHT window.
Summary of Contents for B 130
Page 1: ...p n AWT35 500632 issue AA July 2010 MODEL B 130 Counting Scale User Manual...
Page 6: ......
Page 21: ...16...