Locker Options – 77000 Series
Installation Instructions
Lockers Installation Order with Fillers
Generally, the installation of lockers should start with the corners
where locker rows come together at a right angle. After installing the
top corner fillers, build the rows outward from the corners
incorporating gaps and front vertical fillers where needed. Lastly,
install the top in-line fillers. Locker fillers may be cut to special sizes
for custom installations.
Top Fillers – Corners
Top corner fillers are used where two (2) lockers come together in a
right angle in a corner. The flat top corner filler and the sloping hood
corner filler attach in the same manner. After aligning the two (2)
lockers, place the corner filler on the top of the lockers as shown in
the illustration. Attach the fillers with six (6) #8 TEK self-drilling
screws through the existing holes in the top corner filler.
Front Fillers - Vertical
Vertical front fillers are used where a gap occurs in the row of in-line
lockers. The vertical front filler attaches in the same manner in both
the flat top lockers and the sloping hood lockers. Cut the wide front
filler panel to the appropriate width, if necessary, for the size of the
gap between lockers. Align the front filler panel against the side of
one locker at the front vertical corner and the angle slip joint against
the side of the other locker at its front vertical corner. Attach each of
the two (2) pieces with #8 TEK self-drilling screws through the holes
provided in the vertical front filler pieces. One of the two lockers is
then moved into place while guiding the vertical edge of the wide filler
panel into the angle slip joint