salmson ACSON Installation And Starting Instructions Download Page 8

8

- After a priming time varying between a few seconds and three

minutes, according to installation conditions, read off the pressure

on the pressure gauge. This should be around the maximum value

for the pump. While it is running, the "ON" check light will remain lit.

- Shut the tap; the pump will stop after about three to five seconds.

Only the voltage indicator ”POWER” will stay lit.

- As soon as a tap is opened again, the pump will restart automati-

cally.

Any operational irregularities after these operations are due to faulty

priming of the pump. The safety system activation check light

”ALARM” will come on. Fill the pump. Press the "RESET" button.

Adjusting the cut-in pressure.

If the head of water HR or HC (

See FIG. 2

) is higher than 15 m, the

pump cannot start up again at the cut-in pressure pre-set at the fac-

tory. In this case, it is necessary to adjust this setting using the screw

(

See FIG. 5 - 7

). With the pump stopped and the tap open, read off

the pressure due to the head of water on the pressure gauge and

turn the screw t, until the pump starts up.

Fine-tune the setting during other start-stop cycles; read off the cut-

in pressure on the pressure gauge and turn the screw in the desired

direction (+ or -).

The maximum pump pressure should be 0.5 bar higher than the cut-

in pressure of the automatic control.

Take  care : The automatic control only regulates the pump cut-in

pressure. It does not affect the pressure in the installation, which

depends only on the characteristics of the pump.

Checking operation

Open and then shut one or more taps in the network and make sure

that the pump-automatic control assembly is operating correctly.

If there is a power cut, the automatic control will

need to be reset manually, by pressing the "RESET"

button, when power returns (only in case of not automatic reset).

7.  MAINTENANCE - SERVICING

7.1 Maintenance

The usual conditions apply for exchange of the machine if it proves

defective while under guarantee.

7.2 Spare part 

Electronic board.

7.3 Disassembly- Reassembly

Maintenance-free equipment.

5.2 Mounting (See FIG. 2)

Before connecting the hydraulic connector, it is

essential to fill the pump completely.

Put the automatic control in a vertical position

(vertical suction, horizontal discharge).

It can be connected either directly on to the pump discharge or

onto a rigid pipe between the pump and the first tap.

5.3 Hydraulic connections

The automatic control can be connected directly onto the  pump

discharge (if DNR is 1") or onto a rigid pipe (supported) between the

pump and the first tap.

We  recommend that a flexible tube be fitted at the outlet of the

automatic control to avoid any stress on the body.

The automatic control can be used with a pump connected to the

town water supply without a dry running protection device (with

town pressure not exceeding 1 bar),  as this is built in to the automa-

tic control. For the same reason, a non-return or discharge valve bet-

ween the pump and the automatic control is not necessary.

5.4 Electrical connections

Electrical connections and checks must be carried out by a

qualified electrician in accordance with local standards in

force.

- Check that the supply voltage is 220-240 V (50 Hz or 60 Hz). To access

the connection terminal, unscrew the four screws in the terminal box

cover.

- Connections are by three-strand cable WITH OBLIGATORY EART.

- Connect the pump motor and the mains supply in accordance

with the diagram printed on the plate inside. (

See FIG 3

).

DO NOT FORGET TO CONNECT THE EARTHINGS.

Three phase supply

The automatic control can be used with three phase pumps (or

single phase pumps with current higher than 10 A) using a contactor.

In this case, connections will be made according to the diagram

(

See FIG. 4

).

6.  STARTING UP

6.1 Before starting

Check that the pump is full, to make sure of cor-

rect priming.

- Connect the automatic control to the electricity supply; the power

check light "POWER" will come on.

- A self-priming pump sucking at a depth of 8 metres can take two to

three minutes to start up. During this operation, keep the "RESET" key

pressed down.

6.2 Operation

- Open the installation tap slightly; the pump will start immediately.

ATTENTION !

ATTENTION !

ATTENTION !

ATTENTION !

ENGLISH

Summary of Contents for ACSON

Page 1: ...ACSON INSTALLATION ET MISE EN SERVICE DU DISPOSITIF D AUTOMATISME ACSON INSTALLATION AND STARTING INSTRUCTIONS FOR ACSON AUTOMATIC CONTROL DEVICE FRANCAIS ENGLISH N M S STOCK N 4 048 462 Ed 3 08 00...

Page 2: ...TENS O E COMPATIBILIDADE ELECTROMAGN TICA POMPES SALMSON declara que os materiais designados no presente cat logo obedecem s disposi es da directiva BAIXA TENS O modificada Directiva 73 23 CEE e COMP...

Page 3: ...C HR 1x220 240 V ou or 0 1 3 6 3 2 12 1 13 5 FIG 1 220 240 V 50 60 Hz L1 N U M 1 V 4 8 10 11 9 FIG 3 FIG 2 220 240 V 50 60 Hz U V 220 240 V 50 60 Hz 10A MAX 3 380 400 V 50 60 Hz L1 L1 L2 L3 N N U M V...

Page 4: ...contre les chocs et toutes influences ext rieures humidit gel etc 4 PRODUITS ET ACCESSOIRES DN orifice entr e 1 m le DN orifice sortie 1 m le 4 1 Descriptif technique Voir FIG 1 et 5 1 Orifice d aspi...

Page 5: ...urant 7 MAINTENANCE ENTRETIEN 7 1 Maintenance Echange standard de l appareil reconnu d fectueurx pendant sa p riode garantie 7 2 Pi ce de rechange Platine lectronique 7 3 D montage remontage Mat riel...

Page 6: ...aspiration de la pompe Le manom tre va indiquer une pression inf rieure la normale ou une oscillation constante Le syst me de s curit va agir en arr tant le fonctionnement de la pompe l indi cateur l...

Page 7: ...O ring on the shaft 13 and then secure the pressure gauge using the two mounting screws Close off the opposite port with the plug screw without O ring or Teflon 1 G N RALIT S 1 1 Applications The Acso...

Page 8: ...sembly Reassembly Maintenance free equipment 5 2 Mounting See FIG 2 Before connecting the hydraulic connector it is essential to fill the pump completely Put the automatic control in a vertical positi...

Page 9: ...tion The safety system prevents pump operation and the check light ALARM comes on g The HR or HC heads of water are higher than 15 m and the factory pre set cut in threshold has not been adjusted a Sm...

Page 10: ...10 NOTES...

Page 11: ...11 NOTES...

Page 12: ...L 351 22 208 0350 FAX 351 22 200 1469 P S SEA Pte Lte SINGAPORE 1 Claymore Drive 10 03 Orchard Towers 229594 TEL 65 834 0688 FAX 65 834 0677 salmson_pumps pacific net sg SALMSON IRELAND Enterprise cen...

Reviews: