background image

EN |

 9

VSA 3.0_VSA EKO v2019.04   

DECLARATION OF CONFOMITY

Manufacturer

SALDA, UAB

Ragainės g. 100

LT-78109 Šiauliai, Lithuania

Tel.: +370 41 540415

www.salda.lt

Hereby confirms that the following products - Air handling units:

Fan*

(where by “*” indicates possible unit installation type and modification)

Provided it was delivered and installed in the facility in accordance with the included installation instructions, comply

with all applicable requirements in the following directives:

Machinery Directive 2006/42/EC

Low Voltage Directive 2006/95/EC

EMC Directive 2014/30/EU

The following regulations are applied in applicable parts:

Ecodesign requirements for ventilation units Nr. 1253/2014;

Energy labeling of residential units Nr. 1254/2014.

The following harmonized standards are applied in applicable parts:

LST EN ISO 12100 - Safety of machinery - General principles for design - Risk assessment and risk reduction.

LST EN 60204-1 - Safety of machinery - Electrical equipment of machines - Part 1: General requirements.

LST EN 60335-1 - Household and similar electrical appliances. Safety. Part 1: General requirements.

LST EN 60529 - Degrees of protection provided by enclosures (IP code).

LST EN 60034-5 - Rotating electrical machines. Part 5: Degrees of protection provided by the integral design of rotating electrical machines (IP

code)

LST EN 61000-6-2 - Electromagnetic compatibility (EMC) -- Part 6-2: Generic standards - Immunity for industrial environments.

LST EN 61000-6-3 - Electromagnetic compatibility (EMC) -- Part 6-3: Generic standards - Emission standard for residential, commercial and

light-industrial environments. 

Should any alterations be made in the products, this declaration will no longer apply.

Notified body: 

VšĮ Technikos priežiūros tarnyba, Naugarduko g. 41, LT – 03227 Vilnius, Lithuania, identification number 1399.

Quality:

  Salda UAB activities are in line with the international quality management system standard 

ISO 9001:2015. 

Date                          2019-02-01

Giedrius Taujenis

Director product development

Summary of Contents for VSA 3.0 Series

Page 1: ...VSA 3 0 VSA EKO EN MOUNTING AND INSTALLATION INSTRUCTION...

Page 2: ...he manufacturer or his representative The device can only work under following conditions It is strictly prohibited to use the device not for its purpose or not under provided working conditions witho...

Page 3: ...e use would be ensured The device can be connected to pull the air directly from the ventilated room fig 01 or from the air duct system fig 02 It is necessary to ensure protection from contacting work...

Page 4: ...s and are connected to the electricity This may pose a risk to the human health and life That is why safety require ments have to be followed while installing If you have any doubts on the safety of t...

Page 5: ...N line voltage 230V C C capacitor TK jumper YE GN BN PE N L BU N RD L YE GN yellow green RD red BN braun SP2 L 0k Protective earth PE L1 N line voltage 230V C C capacitor YE GN BN PE N L BU N RD L YE...

Page 6: ...er but the device does not start do the following Wait 10 20 min until the engine cools down If the electrical current was not disconnected and after 10 20 min the engine starts itself this means that...

Page 7: ...tection class IP 44 IP 44 IP 44 IP 44 IP 44 IP 44 wiring diagram 2 1 2 1 1 1 VSA EKO 190 220 225 250 phase voltage 50 Hz VAC 1 230 1 230 1 230 1 230 power kW 0 084 0 097 0 17 0 360 current A 0 66 0 77...

Page 8: ...erage kWh 107 143 70 123 AEC cold kWh 107 143 70 123 AEC warm kWh 107 143 70 123 AHS Average kWh a 2830 2830 2830 2830 AHS Cold kWh a 5536 5536 5536 5536 AHS Warm kWh a 1280 1280 1280 1280 ErP Complia...

Page 9: ...nt and risk reduction LST EN 60204 1 Safety of machinery Electrical equipment of machines Part 1 General requirements LST EN 60335 1 Household and similar electrical appliances Safety Part 1 General r...

Page 10: ...the equipment to manufacturer Delivery costs should be covered by customer Manufacturer reserves the right to change this technical passport any time without prior notice if some typographic errors or...

Page 11: ...11 VSA 3 0_VSA EKO v2019 04...

Page 12: ...000152 UNIT S MAINTENANCE TABLE Product name lot number Instalation Interval Date Fan cleaning Once a year Heat exchanger cleaning Once a year Filter replacement Every 3 4 months Look at the product l...