background image

| EN

VSA 3.0_VSA EKO v2019.04

ECODESIGN DATA TABLE

VSA

190 L 3.0

190 S 3.0

220 M 3.0

220 S 3.0

Specific energy consumption (SEC) cold

[ kWh/m2a ] -52,7

-51,8

-53,6

-52,3

Specific energy consumption (SEC) average

[ kWh/m2a ] -25,6

-24,7

-26,6

-25,2

Specific energy consumption (SEC) warm

[ kWh/m2a ] -10,1

-9,2

-11,1

-9,7

Declared typology

Unidirectional

Unidirectional

Unidirectional

Unidirectional

Type of drive installed (fan)

Variable

Variable

Variable

Variable

Type of heat recovery system

N/A

N/A

N/A

N/A

Thermal efficiency of heat recovery

[ % ]

N/A

N/A

N/A

N/A

Maximum flow rate

 [ m3/h ]

350

216

670

335

Electric power input of the fan drive at maxi

-

mum flow rate

[ W ]

74

49

106

67

Sound power level (Lwa)

[ dB(A) ]

62

60

63

61

Reference flow

[ m3/s ]

0,07

0,04

0,13

0,07

Reference pressure difference

[ Pa ]

50

50

50

50

SPI

[ W/(m3/h) ] 0,16

0,22

0,11

0,19

Control factor and control typology

0,65

0,65

0,65

0,65

Declared maximum internal leakage rates

[ % ]

N/A

N/A

N/A

N/A

Declared maximum external leakage rates

[ % ]

<1

<1

<1

<1

Possition and description of visual filter warn

-

ing for RVU’s

N/A

N/A

N/A

N/A

AEC average

[ kWh ]

107

143

70

123

AEC cold

[ kWh ]

107

143

70

123

AEC warm

[ kWh ]

107

143

70

123

AHS Average

[ kWh/a ]

2830

2830

2830

2830

AHS Cold

[ kWh/a ]

5536

5536

5536

5536

AHS Warm

[ kWh/a ]

1280

1280

1280

1280

ErP Compliance

2018

2018

2018

2018

Internet address for disassembly instructions

www.salda lt

VSA

225 L 3.0

250 L 3.0

190 EKO

220 EKO

225 EKO

250 EKO

Declared typology

Unidirec

-

tional

Unidirec

-

tional

Unidirec

-

tional

Unidirec

-

tional

Unidirec

-

tional

Unidirec

-

tional

Type of drive

External 

MSD or 

VSD

External 

MSD or 

VSD

External 

MSD or 

VSD

External 

MSD or 

VSD

External 

MSD or 

VSD

External 

MSD or 

VSD

Type of HRS

N/A

N/A

N/A

N/A

N/A

N/A

Nominal NRVU flow rate

[ m3/s ]

0,15

0,15

0,08

0,12

0,15

0,28

Effective electric power input

[ kW ]

0,13

0,21

0,08

0,1

0,16

0,36

SFPint

[ W/(m3/s) ]

N/A

N/A

N/A

N/A

N/A

N/A

Face velocity

[ m/s ]

0

0

0

0

0

0

Normal external pressure

[ Pa ]

316

461

361

278

472

481

Internal pressure drop of ventilation compo-

nents

[ Pa ]

N/A

N/A

N/A

N/A

N/A

N/A

Static efficiency of fans used in accordance 

with Regulation No 327/2011

[ % ]

34,9

32,4

36,9

34,8

43,1

37

Declared maximum external leakage

[ % ]

<1

<1

<1

<1

<1

<1

Casing sound power level (Lwa)

[ dB(A) ]

73

75

72

73

79

82

ErP Compliance

2018

2018

2018

2018

2018

2018

Internet address for disassembly instructions

www.salda lt

Summary of Contents for VSA 3.0 Series

Page 1: ...VSA 3 0 VSA EKO EN MOUNTING AND INSTALLATION INSTRUCTION...

Page 2: ...he manufacturer or his representative The device can only work under following conditions It is strictly prohibited to use the device not for its purpose or not under provided working conditions witho...

Page 3: ...e use would be ensured The device can be connected to pull the air directly from the ventilated room fig 01 or from the air duct system fig 02 It is necessary to ensure protection from contacting work...

Page 4: ...s and are connected to the electricity This may pose a risk to the human health and life That is why safety require ments have to be followed while installing If you have any doubts on the safety of t...

Page 5: ...N line voltage 230V C C capacitor TK jumper YE GN BN PE N L BU N RD L YE GN yellow green RD red BN braun SP2 L 0k Protective earth PE L1 N line voltage 230V C C capacitor YE GN BN PE N L BU N RD L YE...

Page 6: ...er but the device does not start do the following Wait 10 20 min until the engine cools down If the electrical current was not disconnected and after 10 20 min the engine starts itself this means that...

Page 7: ...tection class IP 44 IP 44 IP 44 IP 44 IP 44 IP 44 wiring diagram 2 1 2 1 1 1 VSA EKO 190 220 225 250 phase voltage 50 Hz VAC 1 230 1 230 1 230 1 230 power kW 0 084 0 097 0 17 0 360 current A 0 66 0 77...

Page 8: ...erage kWh 107 143 70 123 AEC cold kWh 107 143 70 123 AEC warm kWh 107 143 70 123 AHS Average kWh a 2830 2830 2830 2830 AHS Cold kWh a 5536 5536 5536 5536 AHS Warm kWh a 1280 1280 1280 1280 ErP Complia...

Page 9: ...nt and risk reduction LST EN 60204 1 Safety of machinery Electrical equipment of machines Part 1 General requirements LST EN 60335 1 Household and similar electrical appliances Safety Part 1 General r...

Page 10: ...the equipment to manufacturer Delivery costs should be covered by customer Manufacturer reserves the right to change this technical passport any time without prior notice if some typographic errors or...

Page 11: ...11 VSA 3 0_VSA EKO v2019 04...

Page 12: ...000152 UNIT S MAINTENANCE TABLE Product name lot number Instalation Interval Date Fan cleaning Once a year Heat exchanger cleaning Once a year Filter replacement Every 3 4 months Look at the product l...