background image

10 

| EN

KUB T120_KUB EKO v2019.04

WIRING DIAGRAM

UAB "SALDA"

Lap� sk.

Lapas

Raidė

Data

Para�as

Dok .Nr.

Lapas

Keit.

Ventiliatori� jungimas

1

3

5

2

4

6

TK TK

PE

PE

L1

L2

L3

TK TK

PE

L3

L2

L1

U1

V1

W2

U2

3xNC   140

°

C

500 V

 AC; 2,

5 A

L1

L2

PE

TK TK

W1

L3

V2

3f, 400V

1

3

5

2

4

6

TK TK

PE

PE

L1

L2

L3

TK TK

PE

L3

L2

L1

U1

V1

W2

U2

L1

L2

PE

TK TK

W1

L3

V2

3f, 230V

3xNC   140

°

C

500 V

 AC; 2,

5 A

KUB-3

KUB-4

KUB-2

1f, 230V

1

3

2

4

TK TK

PE

PE

L1

L2

TK TK

PE

N

L

U1

V1

W2

U2

NC   140

°

C

500 V

 AC; 2,

5 A

L

N

PE

TK TK

W1

V2

C

Q

~1M

3x400V

3x230V

Q

~3M

Q

~3M

KUB-120 ventiliatori�
jungimo bųdai

Q - saugumo jungiklis
M - ventiliatoriaus variklis

KUB-On/Off-TK-3k

1

3

5

2

4

6

TK TK

PE

PE

L1

L2

L3

TK TK

PE

L3

L2

L1

U1

V1

W2

U2

L1

L2

PE

TK TK

W1

L3

V2

3f, 400V

3xNC   140

°

C

500 V

 AC; 2,

5 A

KUB-5

3x400V

Q

~3M

Gaminys

Schemos nr.

KUB 630-4L3 T120

KUB-5

KUB 355-4L3 T120
KUB 400-4L3 T120
KUB 500-4L3 T120
KUB 560-4L3 T120

KUB-3
KUB-4

KUB-3

KUB 450-4L3 T120

KUB 355-4L1 T120
KUB 400-4L1 T120

KUB-1

KUB 450-4L1 T120
KUB 500-4L1 T120

KUB-2

KUB-1

1f, 230V

1

3

2

4

TK TK

PE

PE

L1

L2

TK TK

PE

N

L

U1

Z1

Z2

U2

NC   140

°

C

500 V

 AC; 2,

5 A

L

N

PE

TK TK

C

Q

~1M

5

6

L3

5

6

L3

S

CRE

E

N CABL

E

S

CRE

E

N CABL

E

S

CRE

E

N CABL

E

S

CRE

E

N CABL

E

S

CRE

E

N CABL

E

Tikrino

A.Ratkus

14-04-22

14-04-22

M.Jasaitis

Parengė

UAB "SALDA"

Lap� sk.

Lapas

Raidė

Data

Para�as

Dok .Nr.

Lapas

Keit.

Ventiliatori� jungimas

1

3

5

2

4

6

TK TK

PE

PE

L1

L2

L3

TK TK

PE

L3

L2

L1

U1

V1

W2

U2

3xNC   140

°

C

500 V

 AC; 2,

5 A

L1

L2

PE

TK TK

W1

L3

V2

3f, 400V

1

3

5

2

4

6

TK TK

PE

PE

L1

L2

L3

TK TK

PE

L3

L2

L1

U1

V1

W2

U2

L1

L2

PE

TK TK

W1

L3

V2

3f, 230V

3xNC   140

°

C

500 V

 AC; 2,

5 A

KUB-3

KUB-4

KUB-2

1f, 230V

1

3

2

4

TK TK

PE

PE

L1

L2

TK TK

PE

N

L

U1

V1

W2

U2

NC   140

°

C

500 V

 AC; 2,

5 A

L

N

PE

TK TK

W1

V2

C

Q

~1M

3x400V

3x230V

Q

~3M

Q

~3M

KUB-120 ventiliatori�
jungimo bųdai

Q - saugumo jungiklis
M - ventiliatoriaus variklis

KUB-On/Off-TK-3k

1

3

5

2

4

6

TK TK

PE

PE

L1

L2

L3

TK TK

PE

L3

L2

L1

U1

V1

W2

U2

L1

L2

PE

TK TK

W1

L3

V2

3f, 400V

3xNC   140

°

C

500 V

 AC; 2,

5 A

KUB-5

3x400V

Q

~3M

Gaminys

Schemos nr.

KUB 630-4L3 T120

KUB-5

KUB 355-4L3 T120
KUB 400-4L3 T120
KUB 500-4L3 T120
KUB 560-4L3 T120

KUB-3
KUB-4

KUB-3

KUB 450-4L3 T120

KUB 355-4L1 T120
KUB 400-4L1 T120

KUB-1

KUB 450-4L1 T120
KUB 500-4L1 T120

KUB-2

KUB-1

1f, 230V

1

3

2

4

TK TK

PE

PE

L1

L2

TK TK

PE

N

L

U1

Z1

Z2

U2

NC   140

°

C

500 V

 AC; 2,

5 A

L

N

PE

TK TK

C

Q

~1M

5

6

L3

5

6

L3

S

CRE

E

N CABL

E

S

CRE

E

N CABL

E

S

CRE

E

N CABL

E

S

CRE

E

N CABL

E

S

CRE

E

N CABL

E

Tikrino

A.Ratkus

14-04-22

14-04-22

M.Jasaitis

Parengė

UAB "SALDA"

Lap� sk.

Lapas

Raidė

Data

Para�as

Dok .Nr.

Lapas

Keit.

Ventiliatori� jungimas

1

3

5

2

4

6

TK TK

PE

PE

L1

L2

L3

TK TK

PE

L3

L2

L1

U1

V1

W2

U2

3xNC   140

°

C

500 V

 AC; 2,

5 A

L1

L2

PE

TK TK

W1

L3

V2

3f, 400V

1

3

5

2

4

6

TK TK

PE

PE

L1

L2

L3

TK TK

PE

L3

L2

L1

U1

V1

W2

U2

L1

L2

PE

TK TK

W1

L3

V2

3f, 230V

3xNC   140

°

C

500 V

 AC; 2,

5 A

KUB-3

KUB-4

KUB-2

1f, 230V

1

3

2

4

TK TK

PE

PE

L1

L2

TK TK

PE

N

L

U1

V1

W2

U2

NC   140

°

C

500 V

 AC; 2,

5 A

L

N

PE

TK TK

W1

V2

C

Q

~1M

3x400V

3x230V

Q

~3M

Q

~3M

KUB-120 ventiliatori�
jungimo bųdai

Q - saugumo jungiklis
M - ventiliatoriaus variklis

KUB-On/Off-TK-3k

1

3

5

2

4

6

TK TK

PE

PE

L1

L2

L3

TK TK

PE

L3

L2

L1

U1

V1

W2

U2

L1

L2

PE

TK TK

W1

L3

V2

3f, 400V

3xNC   140

°

C

500 V

 AC; 2,

5 A

KUB-5

3x400V

Q

~3M

Gaminys

Schemos nr.

KUB 630-4L3 T120

KUB-5

KUB 355-4L3 T120
KUB 400-4L3 T120
KUB 500-4L3 T120
KUB 560-4L3 T120

KUB-3
KUB-4

KUB-3

KUB 450-4L3 T120

KUB 355-4L1 T120
KUB 400-4L1 T120

KUB-1

KUB 450-4L1 T120
KUB 500-4L1 T120

KUB-2

KUB-1

1f, 230V

1

3

2

4

TK TK

PE

PE

L1

L2

TK TK

PE

N

L

U1

Z1

Z2

U2

NC   140

°

C

500 V

 AC; 2,

5 A

L

N

PE

TK TK

C

Q

~1M

5

6

L3

5

6

L3

S

CRE

E

N CABL

E

S

CRE

E

N CABL

E

S

CRE

E

N CABL

E

S

CRE

E

N CABL

E

S

CRE

E

N CABL

E

Tikrino

A.Ratkus

14-04-22

14-04-22

M.Jasaitis

Parengė

#1

#2

#3

Q - switch, M - fan motor

NOTE: Fan with frequency converter (if used) must be connected with screened cable in compliance with EMC standards.

D1

E1

GND

10V

24V

11

14

L1

L2

L3

L1

L2

L

3

/N

24V - DC Out (Imax = 70mA)

10V - DC Out (Imax = 10mA)
D1 - Digital In1
E1 - Analog In1
11,14 - Contact rating max. AC250V, 2A
PE, L1, L2, L3 - line voltage 400V
PE, L1, N - line voltage 230V

10k

W

Input 0-10V

L1

N

P

E

P

E

#4

#5

SLECTION OF POWER SUPPLY CABEL AND PROTECTIVE DEVICE

KUB T120

355-4L3

400-4L3

450-4L3

500-4L3

560-4L3

630-4L3

Cross-section of the power supply 

cable

[mm²]

4x1,0

4x1,0

4x1,0

4x1,0

4x1,0

4x1,5

Protective device; automatic switch

[A]

3P

C4

3P

C4

3P

C4

3P

C4

3P

C6

3P

C10

Summary of Contents for KUB EKO

Page 1: ...KUB T120 KUB EKO EN MOUNTING AND INSTALLATION INSTRUCTION ...

Page 2: ...product is installed and used If the provided information is unclear or any doubts arise regarding safe installation and operation please contact the manufacturer or represent ative The unit shall be operated only under the below listed conditions It is strictly forbidden to use the unit for non designed purposes or in contradiction to the specified working conditions without written permission of...

Page 3: ...c wall insulation of 25 mm ATTENTION It is necessary to use filter before the fan PURPOSE OF THE DEVICE Fan kitchen box ins is used in ventilation systems to extract air from the room free from metal corroding chemicals aggressive substances for zinc plastic rubber hard sticky and fibrous particles Fan box insulated is designed for ventilation and conditioning systems to supply extract to from a r...

Page 4: ...erature Co 40 40 40 40 40 40 min ambient temperature Co 40 40 40 40 40 40 weight kg 33 55 62 66 98 138 motor protection class IP 55 IP 55 IP 55 IP 55 IP 55 IP 55 wiring diagram 1 22 1 22 1 1 22 1 22 3 1 Speed is controlled only with the frequency inverter Motors sandard IE2 2 The provided technical data is by using 1 el connection scheme Using 2 el connection scheme technical data will be differen...

Page 5: ...rn the impeller by hand MECHANICAL CONECTION Installation works shall be performed only by trained and qualified personnel Unit shall be installed firmly and tightly to ensure safe operation Do not connect the elbows in vicinity of the connection flanges of the unit The minimum distance of the straight air duct between the unit and the first branch of the air duct in the suction air duct must be 1...

Page 6: ...otection devices of the motor Before start up of the fan make sure that the above instructions of safety and installation are applied Upon start up of the unit make sure that the motor rotates evenly without vibration and outside noise Upon start up of the unit make sure that the air flow generated by the unit matches the direction s of air indicated on the casing The current used by the motor sha...

Page 7: ...hermal protection was activated Find the cause for motor overheating and eliminate it The fan motor with thermo contact protection stops because of overheating and external protection is activated Allow the motor to cool down for 15 20 minutes Correct the cause for motor overheating Switch the fan again The motor does not switch on again Disconnect the supply voltage Ensure that the impeller is no...

Page 8: ...al output function Ready to run 0 Not ready 1 Digital output auxiliary voltage Digital input output common Output frequency Speed reference 0 10 V Analog input circuit common Two wire sensor transmitter Analog input circuit common Output frequency 0 20 mA Analog output circuit common Signal cable shield screen Reference voltage Relay output 1 No fault Fault 1 Embedded Modbus RTU EIA 485 L1 L2 L3 1...

Page 9: ...l output function Ready to run 0 Not ready 1 Digital output auxiliary voltage Digital input output common Output frequency Speed reference 0 10 V Analog input circuit common Two wire sensor transmitter Analog input circuit common Output frequency 0 20 mA Analog output circuit common Signal cable shield screen Reference voltage Relay output 1 No fault Fault 1 Embedded Modbus RTU EIA 485 L1 L2 L3 1 ...

Page 10: ...ė UAB SAL Lapas Raidė Data Para as Dok Nr Lapas Keit Ventiliatori jungimas 1 3 5 2 4 6 TK TK PE PE L1 L2 L3 TK TK PE L3 L2 L1 U1 V1 W2 U2 3xNC 140 C 500 V AC 2 5 A L1 L2 PE TK TK W1 L3 V2 3f 400V 1 3 5 2 4 6 TK TK PE PE L1 L2 L3 TK TK PE L3 L2 L1 U1 V1 W2 U2 L1 L2 PE TK TK W1 L3 V2 3f 230V 3xNC 140 C 500 V AC 2 5 A KUB 3 KUB 4 KUB 2 1f 230V 1 3 2 4 TK TK PE PE L1 L2 TK TK PE N L U1 V1 W2 U2 NC 140...

Page 11: ...1 52 2 98 SFPint W m3 s N A N A N A N A N A N A Face velocity m s 0 0 0 0 0 0 Normal external pressure Pa 580 422 493 448 494 600 Internal pressure drop of ventilation compo nents Pa N A N A N A N A N A N A Static efficiency of fans used in accordance with Regulation No 327 2011 57 8 48 4 52 1 49 7 54 51 8 Declared maximum external leakage 1 1 1 1 1 1 Casing sound power level Lwa dB A 76 57 59 62 ...

Page 12: ...ent and risk reduction LST EN 60204 1 Safety of machinery Electrical equipment of machines Part 1 General requirements LST EN 60335 1 Household and similar electrical appliances Safety Part 1 General requirements LST EN 60529 Degrees of protection provided by enclosures IP code LST EN 60034 5 Rotating electrical machines Part 5 Degrees of protection provided by the integral design of rotating elec...

Page 13: ... the equipment to manufacturer Delivery costs should be covered by customer Manufacturer reserves the right to change this technical passport any time without prior notice if some typographic errors or inaccurate information is found as well as after improving the apps and or the devices Such changes will be included in the new issues of the technical passport All illustrations are just for inform...

Page 14: ...14 KUB T120_KUB EKO v2019 04 ...

Page 15: ... 15 KUB T120_KUB EKO v2019 04 ...

Page 16: ...AN000151 UNIT S MAINTENANCE TABLE Product name lot number Instalation Interval Date Fan cleaning Once a year Heat exchanger cleaning Once a year Filter replacement Every 3 4 months Look at the product label At least NOTE The purchaser is required to fill in the Product maintenance table ...

Reviews: