14
| EN
AMBERAIR COMPACT RH v2019.08
TV1_P/TV1_
I
T2
TV
1_P/TV1_I
TV
2_P/TV2_I
T4
TV3_P/T
V3_
I
TV2_P/TV2_I
T4
TV3_P/T
V3_I
TV
2_P/TV2_I
Figure 5.4.4 - KPS
M
CO
2
Figure 5.4.5 - Indication for duct connection.
Figure 5.4.6 -
Ventilated premises
ODA - outdoor air; SUP - supply air; ETA - extract air; EHA - exhaust air.
LIST OF COMPONENTS
A1
Fire damper actuator I
FILTER1
Supply air prefilter
A2
Fire damper actuator II
FILTER2
Supply air filter
DTJ
Extract air temperature and humidity sensor
FILTER3
Extract air filter
GK
AHU component
KE1
Electric heater
IV
Exhaust air fan
KE2
Duct Electric heater
KPS
Duct component
KV1
Water heater
M2
Outdoor air damper actuator
KV2
Duct Water heater
M3
Exhaust air damper actuator
M4
Water heater circulatory pump
PE1
Electric preheater
M5
Water heater valve actuator
PS1.1/U5
Supply air prefilter pressure switch/transmitter
M6
Water cooler circulatory pump
PS1.2/U6
Supply air filter pressure switch/transmitter
M7
Water cooler valve actuator
PS2/U7
Extract air filter pressure switch/transmitter
M8
Water heater circulatory pump
PV
Supply air fan
M9
Water heater valve actuator
RR
Rotor heat exchanger
PSS
DX cooler defrost pressure switch
TE
Exhaust air temperature sensor
T1
AHU water heater protection thermostat
TJ
Supply air temperature sensor
T2
AHU water cooling changeover thermostat
TL
Outdoor air temperature sensor
T3
Duct water heater protection thermostat
TR1
Air after rotor temperature sensor
T4
Duct water cooling changeover thermostat
CW1
AHU Water cooler
TV1_P/TV1_I
AHU Water heater temperature sensor (P-on
the pipe/I-into the pipe)
CW2
Duct Water cooler
TV2_P/TV2_I
Duct Water heater/cooler temperature sensor
(P-on the pipe/I-into the pipe)
DX2
DX cooler
5.5. MOUNTING
•
Installation should only be performed by qualified and trained staff.
• When connecting air ducts, consider the notices indicated on the casing of the unit.
• Before connecting to the air duct system, the connection openings of ventilation unit should be closed.
•
When connecting the ducts , you should pay attention to the air flow direction indicated on the device housing.
•
Do not connect the bends close to connection flanges of the unit. The minimum distance of the straight air duct between the unit and the first
branch of the air duct in the supply air duct must be 1xD, in air exhaust duct 3xD, where D is diameter of the air duct.
• It is recommended to use the accessories-holders. This will reduce vibration transmitted by the unit to the air duct system and environment.
•
Enough space must be left for opening of the maintenance door and filter covers.
• If the installed ventilation unit is attached to a wall, it may transmit noise vibrations to the premises. Though the level of noise caused by the
fans is admissible, it is recommended to mount the unit at the distance of 400 mm from the nearest wall. If it is not possible, the mounting of the
unit is recommended on the wall of the room where the level of noise is not important.
• Ducts are connected to the unit in such way that they could be easily disassembled and the heater could be removed from the unit when per-
forming service or repair works.
• Can be installed outside if weather protected. An outdoor air section, OC is available as accessory.