EN |
11
AMBERAIR COMPACT RH v2019.08
Rotor drives and controllers
Variklis OJ-MRHX-3P04-15
Variklis OJ-MRHX-3P08-15
Valdiklis rot. OJ-DRHX-1220-MAD5 8Nm
ZAKVA055
Valdiklis rot. OJ-DRHX-1220-MAD5 4Nm
ZAKVA054
Electrical heaters
Šild. el. AAC 7R-27-3f-NIS-H
ZESAAC027
Šild. el. AAC 7R-27-3f-NIS-V
ZESAAC028
Šild. el. AAC 7R-30-3f-NIS-H
ZESAAC025
Šild. el. AAC 7R-30-3f-NIS-V
ZESAAC026
Šild. el. AAC 7R-51-3F-NIS-H
ZESAAC022
Šild. el. AAC 7R-51-3F-NIS-V
ZESAAC021
Water heaters
Šild. vand. 1 eil. Compact 7 R H
GNGPR168_1155_0
Šild. vand. 2 eil. Compact 7 R H
GNGPR168_1156_0
Šild. vand. 1 eil. Compact 7 R V
GNGPR168_1157_0
Šild. vand. 2 eil. Compact 7 R V
GNGPR168_1158_0
Šild. vand. 3 eil. Compact 7 R V
GNGPR168_1159_0
Water coolers
Aušin. vand. 2 eil. Compact 7 R H
GNGPR168_1161_0
Aušin. vand. 4 eil. Compact 7 R H
GNGPR168_1162_0
Control board
Aut.219.1140-7R-E3-C1
GAUSM219_1140_1140
Aut.219.1141-7R-W-C1
GAUSM219_1140_1141
Aut.219.1145-7R-E-C2
GAUSM219_1140_1145
Aut.219.1142-7R-W-C2
GAUSM219_1140_1142
Filters (Pocket)
Filtras FMK 592x490x350-8 ePM1-85-SG (F9)
ZFEFMK1186
Filtras FMK 592x490x350-7 CORS-85-SA (M5)
ZFEFMK1182
Filtras FMK 592x490x350-7 ePM1-70-SG (F7)
ZFEFMK1185
Filtras FMK 592x490x570-7 ePM1-85-SG (F9)
ZFEFMK1181
Filtras FMK 592x490x570-8 CORS-85-SA (M5)
ZFEFMK1184
Filtras FMK 592x490x570-8 ePM1-70-SG (F7)
ZFEFMK1183
Filters (Panel)
Filtras MPL 592x490x46 ePM1-70 (F7)
ZFEPF237
Filtras MPL 592x490x46 ePM1-85 (F9)
ZFEPF238
Filtras MPL 592x490x46 ePM10-55 (M5)
ZFEPF236
Pre-filters (Panel)
Filtras MPL 592x490x46 CORS-65 (G4)
ZFEPF252
Sensors
Jutiklis temp. TJ1TE-NTC10K3B-4.5x90P-2x6,0mPVC-
FL
PJUT0071
Jutiklis DTJ100.1.50
PJUT0081
Jutiklis temp. TJ1TE-NTC10k3-6x6x22B-2x5.0 m PVC
PJUT0069
Temperaturos jutikliui TJ1-NTC10k3B-6x240S-
2x2.0mPVC-CF
PJUT0076
5. INSTALATION
5.1. RECEPTION OF GOODS
Each device is thoroughly checked before transportation. When receiving goods it is recommended to check whether devices were damaged
during transportation. If damage to the device is identified, immediately inform the representatives of a transport company. Please inform a rep
-
resentative
of the manufacturer, if any deviation from the order is noticed.
5.2. TRANSPORTATION AND STORAGE
• All units are packed in the factory to withstand regular conditions of transportation.
• The package is only for protection purpose!
• When unloading and storing the units, use suitable lifting equipment to avoid damage or injuries. Do not lift units by holding on power supply
cables, connection boxes, air extract or exhaust flanges. Avoid impact and shock overloads. Before installation units must be stored in a dry
room with the relative air humidity not exceeding 70% (at +20 °C) and with an average ambient temperature ranging b5 °C and +30
°C. The place of storage must be protected against dirt and water.
• The units must be transported to the storage or installation site using forklifts.
• The storage is not recommended for a period longer than one year. In case of storage longer than one year, before the installation it is neces-
sary to verify whether the bearings of fans and motor rotate easily (turn the impeller by hand) and if the electric circuit insulation is not damaged
or the moisture is accumulated.
• AmberAir Compact are lifted from the pallet with a forklift or slings, which are inserted through the supporting legs (four corners).
• AmberAir Compact are lifted from the pallet with a forklift at the recesses at the supporting base, or with slings.