![SALAMANDRES SGF 800 Instructions For Use And Installation Download Page 17](http://html1.mh-extra.com/html/salamandres/sgf-800/sgf-800_instructions-for-use-and-installation_801773017.webp)
Gas modification for SGM 600
Gas category table, according to the country of destination of the appliance.
Country of des-
tination
Category
Gas
Pres-
sures
Injector
diameter
By
-
Pass
screw
diameter
Air
setting
ring
France/
Luxembourg
II2E+3+
G20/25
20/25
130
Adjustable
Without
G30/G31
28
-
30/37
85
110
Without
II2E+3B/P
G20/G25
20/25
130
Adjustable
Without
G30/G31
50
75
95
Without
Germany
II2E3B/P
G20/G25
20
130/142
Adjustable
Without
G30/G31
50
75
95
Without
Austria
II2H3B/P
G20
20
130
Adjustable
Without
G30/G31
50
75
95
Without
Sweden/Danemark
II2H3B/P
G20
20
130
Adjustable
Without
Finland
G30/G31
28
-
30/30
85
110
Without
Spain
II2H3+
G20
20
130
Adjustable
Without
G30/G31
28
-
30/37
85
110
Without
II2H3P
G20
20
130
Adjustable
Without
G31
50
75
95
Without
II2L3B/P
G25
25
130
Adjustable
Without
G30/G31
28
-
30/37
85
110
Without
II2L3P
G25
25
130
Adjustable
Without
G31
50
75
95
Without
Norway
I3B/P
G30/G31
28
-
30/30
85
110
Without
Islande/Greece/
Great Britain /Italy
II2H3+
G20
20
130
Adjustable
Without
Portugal
II2H3+
G30/G31
28
-
30/37
85
110
Without
Netherlands
N°injector
Gas
Pressure
Diameter
Injector n°1
G30/G31
Butane/Propane
28
-
30/37
85/100
Injector n°2
G30/G31
Butane/Propane
50
75/100
Injector n°3
G20/G25
Natural gas
20
-
25
130/100
Injector n°4
G25
Natural gas
20
142/100
17
Summary of Contents for SGF 800
Page 22: ...22 Nomenclature SGM 600 Spare parts SGM 600...
Page 23: ...23...
Page 24: ...24 Nomenclature SGM 800 Spare parts SGM 800...
Page 25: ...25...
Page 26: ...26 Nomenclature SGF 800 Spare parts SGF 800...
Page 27: ...27...
Page 28: ...G03228...