ESP CPV pumps to shower 

columns or steam shower 

cabinets

These will be required to operate NEGATIVE 
HEAD where pipework runs above tank.

Figure 12: ESP CPV to a shower column

Typical installations – ESP CPV pumps

Vent and other 

services

No Stop Essex Flange 

MUST be used with an

anti gravity loop at least

250mm in depth

Usable capacity

minimum 50 gallons

per bathroom

Outlets

Inlet

C

H

Air vents, both

hot and cold

Min

600mm

MAX

60°C

Fig 9 ESP CPV pumps to shower or steam

OLD STYLE DO NOT USED

Vent and 

other

services

Inlet

No Stop Essex Flange

MUST be used with an

anti-gravity loop at least

250mm in depth

Cold water storage

H

C

Air  vents, 

both hot 

and cold

MAX

60˚C

600mm or

less possible

negative head

Outlet

Outlet

Usable capacity

minimum 50 gallons

per bathroom

ESP CPV pump to a shower cabinet.
Shower columns and steam shower cabinets 
in larger whole house systems or systems 
with multiple bathrooms will be best served 
by an ESP CPV Super Booster. See Figures  
16, 17 and 18.

ESP CPV single (negative head)

The following systems are best 
accommodated by using a Right ESP CPV 
single pump (the fully integrated option) 
which is complete with a pressure vessel and 
electronic system protection.

Right ESP CPV single pump to boost tank fed 
supplies to instantaneous electric showers 
and water heaters.

Figure 13: Instantaneous electric showers 

and water heaters

600mm or 

less possible 

negative head

Usable capacity

minimum 50 gallons

per bathroom

C

Fig 10 ESP CPV single

OLD STYLE DO NOT USED

Tank fed, pressurised cylinder or Combi boiler 
system with Right ESP CPV single pump to 
boost the hot supply water pressure and cold 
water mains supplies ‘cold’ to shower, bath, 
basin and toilet.

Figure 14: Pressurised cylinder or Combi 

boiler system

Min 

600mm

Incoming cold water mains

Combi

boiler

Usable capacity

minimum 50 gallons

per bathroom

Double acting

non-return valves

must be fitted 

to cold inlets of any

shower valve or

mixer tap

OLD STYLE DO NOT USED

Combi

boiler

Cold water storage

Incoming cold water mains

600mm or less possible 

negative head

Fit an

equilibrium

ball valve

C

Fig 11 Tank fed

Usable capacity

minimum 50 gallons

per bathroom

Double acting

non-return valves

must be fitted

to cold inlets of

any shower valve

or mixer tap

ESP CPV Super Booster  

(super booster pack)

Use the ESP 120 Super Booster for un-vented 
mains pressure systems and pumped cold 
water around the house, these two options 
must be from cold water storage tanks.

Figure 16: Super booster

Vent and 

other 

services

MAX

65°C

C

Washing 

machine

Usable capacity

minimum 50 gallons

per bathroom

H

Vent and

other

services

Cold water storage

Washing

machine

OLD STYLE DO NOT USED

Fig 14 Large whole house

MAX

65˚C

C

H

Usable capacity

minimum 50 gallons

per bathroom

Large whole house system with the ESP CPV 
Super Booster hot and cold pumps mounted 
in the airing cupboard.

Figure 17: Super booster whole house 

systems

C

C

Fig 9 ESP CPV SB

OLD STYLE DO NOT USED

C

C

Cold water storage

Sports Complex with multiple showers.

Figure 18: Super booster to multiple 

showers

MAX

65°C

MAX

65°C

Usable capacity

minimum 50 gallon

per bathroom

Mixer valve

Vent and other 

services

C

H

Vent and

other

services

Mixer

valve

Cold water storage

OLD STYLE DO NOT USED

 

H

MAX

65˚C

MAX

65˚C

C

Usable capacity

minimum 50 gallons

per bathroom

Tank fed (hot) with cold water mains cold 
systems MUST use Right ESP CPV.
Never use an ESP single pump after the 
shower valve or before an open outlet.

Figure 15: Tank fed (hot) with mains cold 

system

MAX

65°C

MAX

65°C

Double action

non return valves

Incoming cold water mains 

Double action

non return valves

Incoming cold

water mains

Cold water storage

Fig 13 Tank fed hot

OLD STYLE DO NOT USED

H

MAX

65˚C

Usable capacity

minimum 50 gallons

per bathroom

SAL6479 Pumps Install DocAW1 .indd   10-11

29/09/2011   11:27

Summary of Contents for RGP

Page 1: ...Postcode 4 What is the approximate cold water storage capacity in gallons Pump serial number Model Date of purchase _____ _____ _____ 5 Where is the pump situated How far is it from the hot water cyli...

Page 2: ...l us implement our engineers recommendation for your installation situation then ask your customer to register When the job is finished tear off the final page of this instruction manual and hand it t...

Page 3: ...an air vent on the supply pipe work to a pump Where the pump is servicing two or more bathrooms the cold water supply to the cylinder must be in 28mm pipe work 2 2 Cold water storage Ensure that the c...

Page 4: ...pump must be connected to the electrical supply using the mains cable with the attached plug This plug must be connected to an accessible socket that has been installed in compliance with BS7671 I E E...

Page 5: ...per bathroom The hot connection must be via an approved side or top entry flange see page 16 Vent and other services Cold water storage MAX 65 C H C Outlet Inlet Outlet Inlet Fig 5 Right pump feeding...

Page 6: ...tive head Usable capacity minimum 50 gallons per bathroom The hot connection must be via an approved side or top entry flange see page 16 Vent and other services Cold water storage MAX 60 C H C Outlet...

Page 7: ...throom C Fig 10 ESP CPV single Tank fed pressurised cylinder or Combi boiler system with Right ESP CPV single pump to boost the hot supply water pressure and cold water mains supplies cold to shower b...

Page 8: ...of cold storage The typical recovery rate of a 1 2 inch high pressure part II BS1212 ball valve is 15PSI 1 0 bar 0 97 galls min 30PSI 2 0 bar 1 34 galls min 40PSI 2 7 bar 1 58 galls min 60PSI 4 0 bar...

Page 9: ...starvation protection pipework arrangements and stored hot water Fortic type tanks and pre assembled units Typically used in very small flats and houses Not usually with sufficient water capacity of...

Page 10: ...of the hot supply water to the pump The No Stop Essex flange is in all circumstances the best option S flange Complete with compression pump and open vent connections Also supplied with an adaptor to...

Page 11: ...is simply achieved by use of a cylinder thermostat and zone valve or direct acting thermostatic valve e g tapstat In systems where the stored hot water temperature is not controlled eg Aga solid fuel...

Page 12: ...V valve Is the temperature set to 65 C maximum Fault Probable cause Recommended solution Reduced intermittent flow Incorrect or no anti aeration flange fitted Check that installation complies with Sal...

Page 13: ...ment which shall in the opinion of the Company have proved defective by reason only of the Company s materials or workmanship providing always that the Company shall be under no obligation whatsoever...

Page 14: ...ion PumpWise guidelines General specification Trouble shooting PumpWise and warranty Freepost RLXE JHHY HLHJ Salamander Pumps Unit 2c Colima Avenue Sunderland SR5 3XE Notes SAL6479 Pumps Install DocAW...