Typical installations – RSP and RHP pumps

Right Shower Pumps (RSP)

Designed purely for showers. The right 
shower pump is best determined by the 
customer’s expectations and choice of 
shower head.

Figure 6: Right pump fitted in loft above 

cylinder outlet

MAX

60°C

Outlets

Inlet

Min

600mm

Usable capacity

minimum 50 gallons

per bathroom

Vent and other 

services

Non-return valve

hot outlet only

Air vents, both

hot and cold

No Stop Essex Flange

MUST be used with an 

anti gravity loop at least

200mm in depth 

C

H

MAX

60˚C

No Stop Essex Flange

MUST be used with an

anti-gravity loop at 

least 200mm in depth

Min 600mm

Vent and

other services

Inlet

Inlet

Outlet

Outlet

Air vents, 

both hot 

and cold

Cold water storage

H

C

Fig 4 Right shower pumps (RSP)

OLD STYLE DO NOT USED

Fit an

equilibrium

ball valve

600mm or 

less possible 

negative head

Positive head

Usable capacity

minimum 50 gallons

per bathroom

The hot

connection

must be via

an approved

side or top

entry flange

(see page 16)

Vent and 

other

services

Cold water storage

MAX

65˚C

H

C

Outlet

Inlet

Outlet

Inlet

Washing

machine

Fig 6 Right whole house pumps (RSP)

OLD STYLE DO NOT USED

Vent 

and other 

services

Usable capacity

minimum 50 gallons

per bathroom

Positive

head

Outlets

Inlet

Washing

machine

MAX

65°C

C

H

The hot

connection

must be via

an approved

side or top

entry flange

see col. 3 page 10

Fit an

equilibrium

ball valve

2 feet or less

possible negative head

The hot

connection

must be via

an approved

side or top

entry flange

see col. 3 page 10

Vent and other 

services

Usable capacity

minimum 50 gallons

per bathroom

Positive head

Outlets

Inlet

MAX

65°C

C

H

2 feet or less

possible negative head

600mm or 

less possible 

negative head

Positive head

Usable capacity

minimum 50 gallons

per bathroom

 

The hot

connection

must be via

an approved

side or top

entry flange

(see page 16)

Vent and 

other

services

Cold water storage

MAX

65˚C

H

C

Outlet

Inlet

Outlet

Inlet

Fig 5 Right pump feeding one shower

OLD STYLE DO NOT USED

 

In positive head systems, allow for increased 
resistance of long pipe runs with multiple 
bends. The natural flow from the shower 
head or other outlets MUST be at least  
1 litre/min per side (hot or cold).

Figure 7

Right whole House Pumps 

(RHP)

Equipped with a bypass loop. Selection of 
the Right whole house pump for a system 
will be determined by the resistance of, 
quantity of and the pressure required by,  
the outlets. 
In these systems 
•  Toilets MUST be fitted with an equilibrium 

ball valve.

Figure 8: Whole house system with any 

RHP twin pump

!

ESP CPV pumps – system operation and 

L.E.D. indication

With electronic system protection  
ESP CPV pumps are the culmination 
of four years intensive research 
to develop advanced pumps 
incorporating micro electronic 
technology and sensors capable of:

•    Positive or negative head operation
•    Supply water temperature sensing
•    Dry run protection
•    Sensing chronic aeration or water 

starvation

•    L.E.D. indication of system function and 

any unforeseen system malfunction

IMPORTANT NOTE

The HOT and COLD pump ends are identified 
by RED (hot) and BLUE (cold) tie wraps.  
See above illustration.

Cold pump end

L.E.D. indication

Hot pump end

Pressure vessel

ESP CPV pumps have been designed 
to protect customers by responding to 
unexpected or unforeseen conditions.
ESP CPV pumps will only be switched ‘OFF’ 
if the unexpected or unforeseen conditions 
are serious.
System operation and system malfunction 
is indicated via five L.E.D’s located on top of 
the pump junction box, see Figure 9.
For ESP CPV pumps only 

NON-RETURN 

VALVES MUST NOT be fitted in the 
discharge pipework between the pump 
outlets and system outlets unless 
specified by Salamander.

Either side of these pumps can be used for 
hot or cold water.

SAL6479 Pumps Install DocAW1 .indd   6-7

29/09/2011   11:27

Summary of Contents for RGP

Page 1: ...Postcode 4 What is the approximate cold water storage capacity in gallons Pump serial number Model Date of purchase _____ _____ _____ 5 Where is the pump situated How far is it from the hot water cyli...

Page 2: ...l us implement our engineers recommendation for your installation situation then ask your customer to register When the job is finished tear off the final page of this instruction manual and hand it t...

Page 3: ...an air vent on the supply pipe work to a pump Where the pump is servicing two or more bathrooms the cold water supply to the cylinder must be in 28mm pipe work 2 2 Cold water storage Ensure that the c...

Page 4: ...pump must be connected to the electrical supply using the mains cable with the attached plug This plug must be connected to an accessible socket that has been installed in compliance with BS7671 I E E...

Page 5: ...per bathroom The hot connection must be via an approved side or top entry flange see page 16 Vent and other services Cold water storage MAX 65 C H C Outlet Inlet Outlet Inlet Fig 5 Right pump feeding...

Page 6: ...tive head Usable capacity minimum 50 gallons per bathroom The hot connection must be via an approved side or top entry flange see page 16 Vent and other services Cold water storage MAX 60 C H C Outlet...

Page 7: ...throom C Fig 10 ESP CPV single Tank fed pressurised cylinder or Combi boiler system with Right ESP CPV single pump to boost the hot supply water pressure and cold water mains supplies cold to shower b...

Page 8: ...of cold storage The typical recovery rate of a 1 2 inch high pressure part II BS1212 ball valve is 15PSI 1 0 bar 0 97 galls min 30PSI 2 0 bar 1 34 galls min 40PSI 2 7 bar 1 58 galls min 60PSI 4 0 bar...

Page 9: ...starvation protection pipework arrangements and stored hot water Fortic type tanks and pre assembled units Typically used in very small flats and houses Not usually with sufficient water capacity of...

Page 10: ...of the hot supply water to the pump The No Stop Essex flange is in all circumstances the best option S flange Complete with compression pump and open vent connections Also supplied with an adaptor to...

Page 11: ...is simply achieved by use of a cylinder thermostat and zone valve or direct acting thermostatic valve e g tapstat In systems where the stored hot water temperature is not controlled eg Aga solid fuel...

Page 12: ...V valve Is the temperature set to 65 C maximum Fault Probable cause Recommended solution Reduced intermittent flow Incorrect or no anti aeration flange fitted Check that installation complies with Sal...

Page 13: ...ment which shall in the opinion of the Company have proved defective by reason only of the Company s materials or workmanship providing always that the Company shall be under no obligation whatsoever...

Page 14: ...ion PumpWise guidelines General specification Trouble shooting PumpWise and warranty Freepost RLXE JHHY HLHJ Salamander Pumps Unit 2c Colima Avenue Sunderland SR5 3XE Notes SAL6479 Pumps Install DocAW...

Reviews: